![]() Fig. 1 |
X-ray image of a tested object is converted into a complete video-signal and the mostinformative TV-frame is recorded by computer. Visual inspection, analysis and processing ofimages are performed with the use of a specially developed program directly on a file and, if necessary, on a paper or magnet carrier. Computer is used to control operation of every introscope unit and to form a data base of tested object video-images. As converters both series and experimental X-ray vidicons with Be input window can be used [1].
TECHNICAL CHARACTERISTICS:
| 7-250 |
for Al for Be (polyethylene) up to 40 up to 80 up to 150 0,5-2,0 | 20 and 8 | 18 and 90 | up to 1,0 | |
The X-ray TV introscope can find wide application in engineering, atomic, chemical, heat power, oil and gas industries.
Example of Reference:
1. Svirjakin D.I., Fifishov N.Ja., Zabavin AW, Ivanov A.A., Saveliev Ju.B. The method of X- vidicon fabrication. Russian patent No. 2034354, 12.08.91.
Abstract Source:
Book of Abstracts, 7th European Conference on Non-Destructive Testing, 26-29 May 1998, ISBN: 87-986898-0-00
Full-Text Source:
Proceedings of the 7th European Conference on Non-Destructive Testing, 26-29 May 1998, ISBN:
Publication Contact:
7th ECNDT, Park Alle 345, DK-2605 Broendby, Denmark, Fax: +45 46 26 70 11, Email: 101373.3414@compuserve.com