Currently a new theory of image formation GDC has been developed, a design of a converter was optimized together with power supply and radiation modes. Some converters have been fabricated with maximum dimension of an input window 500*600 mm and service life above 5000 hours. A number of modular testing and diagnostics systems has been developed having different types of synchronization between radiation source and GDC and different methods ofimage recording from an output window.
![]() Fig.: Design of GDC |
| Principal technical characteristics: | |
| - dose sensitivity | 1 -2 mcR |
| - ultimate resolution | 1,5 line/mm |
| - ultimate line sensitivity | 5-6% |
| - GDC screen luminance at operating frequency 25 Hz | not less than 10 - 20 C |
| - weight (without TV-channel) | less than 20 Kg |
Abstract Source:
Book of Abstracts, 7th European Conference on Non-Destructive Testing, 26-29 May 1998, ISBN: 87-986898-0-00
Full-Text Source:
Proceedings of the 7th European Conference on Non-Destructive Testing, 26-29 May 1998, ISBN:
Publication Contact:
7th ECNDT, Park Alle 345, DK-2605 Broendby, Denmark, Fax: +45 46 26 70 11, Email: 101373.3414@compuserve.com
| NDTnet |