| TABLE OF CONTENTS |
This paper describes the design of an ultrasound camera which has the resolution of 0.1mm. The camera allows the observation of the near surface structures of solid objects and is suitable for the finger ridge pattern imaging (i.e. pattern which is reflected in a fingerprint). The device can be used for a biometric identification of individuals (for access verification). It can also be employed for all other sorts of structures which have ultrasound detectable changes in the near surface structure, both natural and artificial (e.g. created for information recording). The paper describes the current version of the camera and the physical phenomena behind its operation. Presented are also perspectives of further development of the device.