| 4th International Conference of Slovenian Society for NDT Table of Contents | Measurments Of Sound Velocities And Of Hardness On The RCS Hot Leg ElbowJ. Vojvodic - Gvardjancic*, J. Zorko**, I Durkan***Institute for metals and technology, 1000 Ljubljana, Lepi pot 11, Slovenia; **Nuclear power plant Krsko, 8270 Krsko, Slovenia |
CONCLUSION: From the reported we can conclude that it is impossible to measure the ultrasound velocity on the cast material on the curved surfaces without a modification of the ultrasonic probes. The same is conclusive for ultrasonic examination on this material because of high damping.
Keywords: Ultrasonic Testing
Source: Conference Proceedings of the 4th International Conference of the Slovenian Society for Nondestructive Testing, 24 - 25 April 1997, Ljubljana, Slovenia.
Pages:321 - 326
Publisher:
Slovenian Society for Nondestructive Testing, Faculty of Mechanical Engineering, Askerceva 6, SLO 1000 Ljubljana, Slovenia. Tel +386 61 177 12 03, Fax +386 61 218 567, Email: janez.grum@fs.uni-lj.si.