The sizing of the expected flaws should be able to respond to the safety requirements allowing the inspected component to fill its operating conditions rather to fit codes calibration cost.
Using some examples extracted from recent EDF experience of the examination of plant components, the author illustrates how the relation is established between stress analysis, NDT performance definition and carrying out inspection tools.