NDTnet - November 1997, Vol.2 No.11
A COMPLETE ULTRASONIC MEASUREMENT SYSTEM FOR
IN-PROCESS CURE MONITORING AND CONTROL OF COMPOSITES
by David D. Shepard and Kim R. Smith
*
Acknowledgent:
The paper was first published at the Conference on NDE applied to Composite Fabrication,
organized by NTIAC and McDonnell Douglas Aerospace and took place in St. Louis Missouri in Oct '94.
See also all 54 NDE Abstracts of the '94 and '96 Conference Proceedings.
ABSTRACT
Measurements of the ultrasonic sound speed of thermosetting resins and composites can be used as an in-process cure monitoring technique. Ultrasonic measurements have an advantage over other in-process techniques in that ultrasonic sensors do not make contact with the part (thus leaving no imbedded sensor or witness mark) and can make true bulk measurements of the part.
A new commercially available ultrasonic cure monitoring system has been developed which easily enables ultrasonic measurements to be made in compression molding, resin transfer molding, and
autoclave processes. Advancements in ultrasonic sensor technology enable the self-contained
ultrasonic sensor to easily installed in a mold and maintain good coupling to the part during
thermal cycling to 260 C. Data is presented showing the change in ultrasonic sound speed during
the compression molding of a graphite-epoxy prepreg. The data shows a good relationship to the
ionic conductivity and resistivity data collected via dielectric cure monitoring.
TABLE OF CONTENTS
1. INTRODUCTION
Measurements of the ultrasonic sound speed of thermosetting resins and composites can be correlated to the material's viscosity and cure state. The material under test will change state as it undergoes cure. This change of state can be monitored by measuring the velocity of acoustic waves in the material. Previously, use of ultrasonic measurements as a cure monitoring technique had been hindered by poor reliability of ultrasonic transducers under typical processing conditions, especially thermal cycling to elevated temperatures. A new self-contained, in-mold, reusable ultrasonic sensor has been developed. This robust sensor is capable of withstanding hundreds of thermal cycles up to 260 °C. Ultrasonic sound speed measurements may now be routinely made during the processing of thermosets using this new sensor technology. An electronics instrumentation and software package has also been developed for the specific application of making a complete ultrasonic cure monitoring system. The new ultrasonic measurement technology was developed under the National Center for Manufacturing Sciences
(NCMS) Adaptive Process Control of Compression Molded Composites Project. The project
team members consisted of United Technologies, Pratt & Whitney Aircraft; Erie Press Systems;
and Allen Bradley, a Rockwell Automation business. t Jpon successful development and
demonstration of the ultrasonic cure monitoring system in a compression molding process by the
project team, Micromet Instruments, Inc. became a subcontractor for the project to transfer the
technology into a commercially viable sensor and instrumentation system. Micromet Instruments
has acquired a license for the ultrasonic sensor system from NCMS and is currently marketing the
product it has developed, the UCMS-200 Ultrasonic Cure Monitoring System. Pratt & Whitney
and Sikorsky Aircraft are currently evaluating the system for use in controlling the molding of
composite parts.
The ultrasonic sensor is located within the mold and does not contact the part. The sensor is self-
contained and is easily installed by screwing it into a hole in the mold. Once the sensor is
installed, hundreds of runs can be made with no incremental sensor cost and no lay up of sensors
in each part. The ultrasonic technique is ideal for applications where there can be no sensor
imbedded in the part or no witness mark on the outside of the part. The system makes a through-
transmission measurement which measures the bulk properties of the part, even on thick parts of
over 5 cm (2 inches) in thickness. The reusable, non-intrusive nature of the sensor, along with the
ability to measure bulk material properties of thick parts, provide unique features over other in-
process cure monitoring techniques such as dielectric or fiber optic.
2. ULTRASONIC MEASUREMENT TECHNIQUE
The ultrasonic measurement system uses piezoelectric elements to generate an acoustic wave.
High voltage pulses excite the piezoelectric element in the ultrasonic transducer, causing this
element to oscillate at 5 MHz. This creates the acoustic wave that propagates at a material
specific velocity. Whenever the wave reaches a boundary some of the wave is transmitted
through the boundary into the second material, and some of the wave is reflected back. The
transmitted and reflected waves are then collected by the ultrasonic transducers, which also act as
ultrasonic sensors. When an acoustic wave reaches the piezoelectric element, the element
produces a voltage which is the sensor signal. Measurements of sound velocity by through
transmission require two in-line ultrasonic transducers/sensors. One is used to generate the
acoustic pulse while the opposing transducer/sensor records the arrival time of the acoustic wave.
The excitation and detection function is alternated between two transducers. The electronics
allow for multiple signal averaging thereby creating clean signals. The distance between the
opposing sensors is monitored by the system in order to provide accurate distance measurements.
The ultrasonic sound speed is then calculated from the time and distance information.
Sensor and sample geometry are critical to this measurement technique. The wave will change
direction at a boundary if the wave is not perpendicular to the boundary. Therefore the molds .
must be carefully machined to insure the required perpendicularity. Holes for the sensors should
be 2.54 cm in diameter and bored to within approximately 0.6 cm of the mold inner surface. The
bottom surface of the hole must be verv smooth to insure good coupling between the
piezoelectric element of the sensor and the mold. Silicone grease is used to eliminate any air between these mating surfaces, resulting in good coupling.
3. ULTRASONIC MEASUREMENT SYSTEM
The UCMS-200 is a complete stand-alone system consisting of sensors and cabling, a rack-mountable electronics package, and a Windows based LabVIEW software package. A computer is integrated into the electronics package complete with monitor, keyboard, mouse, and disk drives. Figure 1 shows a schematic of the ultrasonic measurement system installed in a compression molding process. An ultrasonic sensor set consists of two sensors located on opposite sides of the mold. For autoclave applications, an ultrasonic sensor is mounted in the tool and the second sensor is mounted in a cull plate which is placed on the sample, beneath the vacuum bag.
The system can measure the ultrasonic sound speed at two different locations using two sets of ultrasonic sensors. Part thickness is monitored using up to four capacitive non-contact displacement probes or linear voltage displacement transducers (LVDT). Accurate measurement of the part thickness is important in accurately calculating the sound speed, especially in processes where the part thickness changes during the cure cycle. Temperature can be measured from two thermocouples.
The LabVIEW based software package enables easy operation of the system and allows the display screen to be customized by the user. Algorithms can be easily written by the user to perform special functions and closed loop control of the process.
4. EXPERIMENTAL RESULTS
The change in sound speed has been correlated with the change in the viscosity of the prepreg (1). Heating the prepreg decreases the material's viscosity and the acoustic wave velocity is decreased. As the material cures, the molecular structure is constrained and supports a higher acoustic wave velocity. The change in ultrasonic sound speed of an epoxy-graphite fiber prepreg during a compression molding process is plotted in Figure 2. The initial decrease in sound speed shows the decrease in viscosity as the prepreg increases in temperature. A broad minimum is seen as the temperature cycle enters a 121 °C hold period. As the temperature is increased to 177 °C, the sound speed increases as curing causes the viscosity of the prepreg to increase. The rate of increase in sc,tind speed then slows as the rate of cure slows and the reaction nears completion.
Dielectric cure monitoring is a widely used, in-process cure monitoring technique involving the measurement of changes in the electrical conductivity of the material. Dielectric measurements have been shown to correlate with the change in viscosity and cure state of epoxy and other thermosetting resins and composites (2,3,4). Dielectric cure monitoring data thus provide a good comparator to the validity of the ultrasonic sound speed in the cure monitoring. Figure 3 compares the ionic conductivity as measured by a Micromet Instruments Eumetric System II.
Microdielectrometer to the ultrasonic sound speed of an epoxy-graphite fiber prepreg (1) The ultrasonic sound speed exhibits a good inverse relationship to the log conductivity data. This inverse relationship is expected since ionic motion is reduced with higher cross-linking of the material, whereas the velocity of the acoustic wave is increased.
Since the sound speed is inversely related to the log conductivity, a plot of the log resistivity (l/log conductivity) should closely track the sound speed. Figure 4 compares the ultrasonic sound speed and log resistivity during the 150 C isothermal cure of a 2.3 mm thick epoxy-glass fiber prepreg. The sound speed and log resisitivity data were measured simultaneously in a compression mold and show an excellent correlation between the two curves. The apparent noise in the sound speed data is the limit of resolution of the time of flight through such a thin sample. On thicker samples, the sound speed resolution will increase, thus increasing the sensitivity of the data to the end of cure.
The excellent correlation of the sound speed to log resistivity can be seen in Figure 5 where the sound speed is plotted as a function of log resistivity during the 150 °C isothermal cure of the glass-epoxy prepreg. A near linear relationship is observed until the sound speed increases above a level of 900 m/s. After this point, the quantification of the sound speed data prohibits a valid assessment of the relative sensitivity of the two measurement techniques to the end of cure.
5. FUTURE WORK
Future applications work will concentrate on resin systems where reaction by-products prevent dielectric cure monitoring from providing useful data, such as phenolic resins and various rubber materials. Thicker samples of epoxy prepreg will be cured to more accurately compare the sensitivity to the end of cure of the ultrasonic sound speed with the log resistivity.
6. CONCLUSIONS
A new commercially available ultrasonic cure monitoring system has been developed which enables ultrasonic measurements to be easily made during the processing of therrnosets in presses, autoclaves, and RTM processes. New, easy to install, self-contained ultrasonic sensors maintain good coupling to the mold during thermal cycling to 260 C. The non-intrusive ultrasonic sensors do not contact the part and thus leave no mark on the part or sensor embedded in the part. The ultrasonic measurements provide a bulk measurement which correlates with the change in material viscosity and correlates well with dielectric cure monitoring data. The ultrasonic cure monitoring system can be used for production closod-loop control of thermoset composite processing.
7. REFERENCES
- W. Veronesi, 41st Sagamore Conference (1994.)
- J. Gotro, NATAS Conference, 19, 523 (1990)
- D.R. Day and D.D. Shepard, NATAS Conference, 16, 52 (1987)
- D.R. Day, D.D. Shepard and K.J. Craven, International SAMPE Technical Conference, 22, 724 (1990).
ACKNOWLEDGMENTS
This effort was sponsored by the Manufacturing Technology Directorate, Wright Laboratory (WL/MTX), Air Force Materiel Command, USAF, under cooperative agreement award(s) to NCMS. The U. S. Government is authorized to reproduce and distribute reprints for Governmental purposes notwithstanding any copyright notation thereon. The views and conclusions contained herein are those of the authors and should not oe interpreted as necessarily representing the official policies or endorsements, either expressed or implied, of Wright Laboratory or the U. S. Government.
AUTHORS
Acknowledgent:
The paper was first published at the
Conference on NDE applied to Composite Fabrication,
organized by NTIAC and McDonnell Douglas Aerospace and took place in St. Louis Missouri in Oct '94.
See also all 54 NDE Abstracts of the '94 and '96 Conference Proceedings.
|Top to this page|
For more information see: NDT in Aerospace - UTonline 11/97
© Copyright 1. Nov 1997 Rolf Diederichs,
rd@ndt.net
/DB:Article /AU:Shepard_D_D /AU:Smith_K_R /CN:US /CT:UT /CT:instrument /CT:process /CT:composite /ED:1997-11