Topics
|
|
|
Tu.1.2.1
|
A Perspective on a Nuclear Future – The Plants and the Professionals
Modeen, D.J., Electric Power Research Institute, Charlotte, NC (USA) Ammirato, F., Electric Power Research Institute, Charlotte, NC (USA)
|
Abstract
|
|
Tu.1.2.2
|
GETTING READY FOR PSI IN OLKILUOTO 3 ON THE NEW EPR POWER PLANT IN FINLAND
Laube, J., intelligeNDT Systems & Services, Erlangen
(Germany)
Tchilian, J.-M., Framatome ANP, Paris la Défense (France) Guse, G., intelligeNDT Systems & Services, Erlangen
(Germany)
Hernandez, J., Intercontrole Framatome, Ringis Cedex (France) Hukkanen, K., Teollisuuden Voima, Olikuluoto (Finland)
|
Abstract
|
|
Tu.1.2.3
|
EXPERIENCE WITH ENHANCED ANALYSIS TOOLS BASED ON UT-DATA COLLECTED WITH THE SAPHIR-UT SYSTEM ON COMPLEX GEOMETRIES
Mohr, F., intelligeNDT Systems & Services, Erlangen
(Germany)
Voskamp, R., E.ON Kernkraft, Stadland
(Germany)
Guse, G., intelligeNDT Systems & Services, Erlangen
(Germany)
Schirner, G., intelligeNDT Systems & Services, Erlangen
(Germany)
|
without manuscript
|
|
Tu.1.2.4
|
THE JASPER SYSTEM, AN INNOVATING COMPETITIVE TOOL FOR ROD CLUSTER CONTROL ASSEMBLY (RCCA) IN-SERVICE INSPECTION
Pasquier, T., Intercontrole Framatome, Ringis Cedex (France) Delpouve, W., Framatome ANP, Chalon sur Saone (France) Degrave, P., Intercontrole Framatome, Ringis Cedex (France)
|
Manuscript
|
|
We.1.2.1
|
Recent advances in automated ultrasonic inspection of Magnox power stations
Wooldridge, T., British Nuclear Group, South Gloucestershire (United Kingdom)
|
Manuscript
|
|
We.1.2.2
|
Inspection of thick part with Phased Array Volume Focusing technique
Braconnier, D., KJTD Co., Higashiaosaka Osaka (Japan) Murakami, T., KJTD Co., Higashiaosaka Osaka (Japan) Yonetsiji, E., KJTD Co., Higashiaosaka Osaka (Japan)
|
Manuscript
|
|
We.1.2.3
|
Piping inspection using a smart flexible phased array
Poidevin, C., CEA, Gif sur Yvette (France) Casula, O., CEA, Gif sur Yvette (France) Abittan, E., EDF Generation, Saint-Denis-Cedex 1 (France)
|
Manuscript
|
|
We.1.2.4
|
Ultrasonic evaluation of status of nuclear reactors cooled by liquid metal
Jasiuniene, E., Kaunas University of Technology, Kaunas (Lithuania) Kazys, R., Kaunas University of Technology, Kaunas (Lithuania) Mazeika, L., Kaunas University of Technology, Kaunas (Lithuania) Sliteris, R., Kaunas University of Technology, Kaunas (Lithuania) Voleisis, A., Kaunas University of Technology, Kaunas (Lithuania) Ait Abderrahim, H., Studiecentrum voor Kernernergie, Mol (Belgium) Dierckx, M., Studiecentrum voor Kernernergie, Mol (Belgium)
|
Manuscript
|
|
We.1.2.5
|
THE INTEGRATION OF PLANT CONDITION ASSESSMENT WITH RISK MANAGEMENT PROGRAMMES
Lilley, J., Veritec Sonomatic, Warrington (United Kingdom)
|
Manuscript
|
|
We.3.2.1
|
THE EVOLUTION OF MECHANIZED INSPECTION OF REACTOR COMPONENTS IN GERMANY
Fischer, E., intelligeNDT Systems & Services, Erlangen
(Germany)
Engl, G., intelligeNDT Systems & Services, Erlangen
(Germany)
|
without manuscript
|
|
We.3.2.2
|
QUALIFICATION OF NDT TECHNIQUES FOR IN-SERVICE INSPECTIONS IN NUCLEAR POWER PLANTS IN ACCORDANCE WITH ENIQ - EXAMPLES AND LESSONS-LEARNED
Just, T., TÜV Nord SysTec, Hamburg
(Germany)
Csapo, G., TÜV Nord SysTec, Hamburg
(Germany)
|
Manuscript
|
|
We.3.2.3
|
Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams
Redmer, B., BAM Berlin
(Germany)
Ewert, U., BAM Berlin
(Germany)
Jakob, M., TÜV IS, München
(Germany)
Neundorf, B., Vattenfall Europe Nuclear Energy GmbH
(Germany)
|
Manuscript
|
|
We.3.2.4
|
Development and Implementation of UT Procedures for nuclear and other applications using TRL Phased Array Probes.
Chardome, V., Vincotte, Vilvoorde (Belgium) Cermak, J., AIB Vinçotte International, Vilvoorde (Belgium) Cruysweegs, E., AIB Vinçotte International, Vilvoorde (Belgium) Delaide, M., Vincotte, Brussels (Belgium) Plateau, M., Vincotte, Brussels (Belgium)
|
Manuscript
|
|
We.3.2.5
|
Ultrasonic Testing Methods and Procedures for Volumetric and Surface Inspection of CANDU Reactor Pressure Tubes
Trelinski, M., Ontario Power Generation, Ajax (Canada)
|
Manuscript
|
|
Th.3.1.1
|
ASSESSMENT OF UT TECHNIQUES FOR CHARACTERIZATION OF STRESS CORROSION CRACKS IN STEAM GENERATOR PARTITION STUBS
Moras, D., Intercontrole Framatome, Ringis Cedex (France) Beroni, C., EDF Generation, Saint-Denis-Cedex 1 (France) Banchet, J., Framatome ANP, Chalon sur Saone (France) Sartre, B., Framatome ANP, Chalon sur Saone (France) Bastin, P., Intercontrole Framatome, Ringis Cedex (France)
|
Manuscript
|
|
Th.3.1.2
|
Eddy Current Signal Analysis Techniques for Assessing Degradation of Support Plate Structures in Nuclear Steam Generators
Obrutsky, L., AECL Chalk River Laboratories, Chalk River, Ontario (Canada) Cassidy, R., AECL Chalk River Laboratories, Chalk River, Ontario (Canada) Sedman, K., Bruce Power, Toronto (Canada) Cazal, M., Nucleolélectrica Argentina Sociedad Anónima, Embalse (Argentina)
|
Manuscript
|
|
Th.3.1.3
|
INNOVATIVE TECHNOLOGIES FOR INSPECTIONS OF COMPLEX STRUCTURES IN NUCLEAR POWER PLANTS, F.E. GAP INSPECTION ON CONTROL ROD HOUSINGS
Kleespies, H., intelligeNDT, Karlstein
(Germany)
Schmidbauer, J., E.ON Kernkraft, Hannover
(Germany)
Mohr, F., intelligeNDT Systems & Services, Erlangen
(Germany)
Pöpperl, D., intelligeNDT Systems & Services, Erlangen
(Germany)
|
without manuscript
|
|
Th.3.1.4
|
Eddy current inspection of WWER steam generator tubes - sensitivity of bobbin probe technique
Krajcovic, R., VUJE, Trnava (Slovakia) Plasek, J., VUJE, Trnava (Slovakia)
|
Manuscript
|
|
Th.3.1.5
|
Application of Guided Wave Technology to Tube Testing
Vogt, T., Guided Ultrasonic Ltd, Nottingham (United Kingdom) Alleyne, D., Guided Ultrasonic Ltd, Nottingham (United Kingdom) Pavlakovic, B., Guided Ultrasonic Ltd, Nottingham (United Kingdom)
|
Manuscript
|
|
Th.4.4.1
|
Reactor Pressure Vessel and Internals become Visible by means of Remote Moulding Inspection, AVT
Olsen, H.-O., Force Technology Sweden, Västeras (Sweden)
|
Manuscript
|
|
Th.4.4.2
|
Effect of crack opening on UT response
Virkkunen, I., Trueflaw, Espoo (Finland) Pitkänen, J., POSIVA OY, Olkiluoto (Finland) Kemppainen, M., Trueflaw, Espoo (Finland)
|
Manuscript
|
|
Th.4.4.3
|
Mobile Computer Tomography for the In-Service Inspection in Nuclear Power Plants
Müller, J., compra, Frechen
(Germany)
Ewert, U., BAM Berlin
(Germany)
Rädel, C., BAM Berlin
(Germany)
Redmer, B., BAM Berlin
(Germany)
Kiechle, H., e.on, Essenbach
(Germany)
|
Manuscript
|
|
Th.4.4.4
|
Ultrasonic estimation of hydride degradation of zirconium pressure tubes of RBMK fuel channel
Sliteris, R., Kaunas University of Technology, Kaunas (Lithuania) Kazys, R., Kaunas University of Technology, Kaunas (Lithuania) Mazeika, L., Kaunas University of Technology, Kaunas (Lithuania) Voleisis, A., Kaunas University of Technology, Kaunas (Lithuania) Dundulis, G., Lithuanian Energy Institute, Kaunas (Lithuania) Grybenas, A., Lithuanian Energy Institute, Kaunas (Lithuania)
|
Manuscript
|
|
P164**
|
Results of the new Eddy Current tester for Steam Generator Applications
Ribes, B., Tecnatom, San Sebastian de los Reyes - Madrid (Spain) Barcenilla, V., Tecnatom, San Sebastian de los Reyes - Madrid (Spain) Hernandez, J., Tecnatom, San Sebastian de los Reyes - Madrid (Spain)
|
Manuscript
|
|
P165**
|
ULTRASONIC IMAGING OF TIGHT CRACK SURFACES BY BACKSCATTERED TRANSVERSE WAVE WITH A FOCUSED TRANSDUCER
Kawashima, K., Nagoya Institute of Technology (Japan) Ito, T., Nagoya Institute of Technology, Nagoya (Japan) Murase, M., Nagoya Institute of Technology, Nagoya (Japan)
|
Manuscript
|
|
P166
|
INSERVICE INSPECTION ON RUSSIAN VVER NUCLEAR POWER PLANTS
Laube, J., intelligeNDT Systems & Services, Erlangen
(Germany)
Grigorijev, M., NIKIMT, Moscow (Russia) Lovchev, V., Rosenergoatom, Moscow (Russia)
|
Abstract
|
|
P167
|
Advanced Inspection of Turbine Components – Important Tool for Steam Turbine Outages
Rauschenbach, H., Siemens PG, Mülheim a.d. Ruhr
(Germany)
Clossen-von Lanken Schulz, M., Siemens PG, Mülheim a.d. Ruhr
(Germany)
Opheys, M., Siemens PG, Mülheim a.d. Ruhr
(Germany)
Siegel, M., Siemens PG, Mülheim a.d. Ruhr
(Germany)
|
Abstract
|
|