The Original Postscript Version (324K) can be downloaded from the NASA Langley Technical Report Server (LTRS).
It is well known in waveguide theory [1-3] that certain modes of sound waves are capable of propagating a relatively long distance in a material of plate configuration, and that their propagation properties are determined in part by the product of sound frequency and plate thickness. Recently, it was found experimentally that, with this thickness certain modes of these plate waves provided a different approach to probe the flaws in a laminate structure, and potential application to the large area disbond and crack inspection.
One of the features which differentiates this measurement from other plate waves techniques is mounting the two transducers on the plate surface at a fixed distance (which be easily larger than 30 cm) and employing an acoustic instead of a transducer to locate the structural flaws. It not unexpected that the insertion of an acoustic damper on plate surface between the transducers results in a decrease amplitude of the received signal; However, it was found in experiments that the amount of decrease when the damper was placed on the unbonded area of a plate assembly was much than that on the bonded areas. Taking advantage of this finding, when the acoustic damping probe (with width of 0.5 in the testing) is scanned back and forth between the transducers as illustrated in Fig. 1, the observed variation amplitude of the received signal can be used to locate the delamination areas.

Fig. 1. Schematic diagram of setup for the plate wave
measurement.
To demonstrate this effect, one of the measurements was done on a plate assembly, half of whose was of two bonded plates and the other half was of single plate. Fig. 2 displays the amplitude variation curve of a mode with phase velocity of 4.35 x 103 m/sec at 1.8 MHz, as a result of scanning. In the figure, x-axis represents the distance of damping probe from the transmitter. Also illustrated in the inset is the geometry of the plate As can be seen, when the damper moved across the double to single plate area or vise versa, the amplitude decreases or increases respectively. Although the amplitude changes were as sharp as expected, which may be due to the phase cancellation of incoming and scattered waves at the the data does reveal the thickness variation and imply that wave mode loses more of its energy in the single plate area than in the double plate area when the local surface was changed by the damper.
To further exhibit this loading effect, measurements were performed on a plate assembly with three unbonded areas, as depicted in Fig. 1, of width 15, 12.5, and 9.5 mm and of thickness 0.2 mm in the thickness direction. a wave mode propagating with the same velocity as the one, the result of scanning is displayed in Fig. 3. The with relative minimum amplitudes in the curve shown with the regions in the fabricated sample where no epoxy was put between the plates. In addition, in a similar a less than 0.8 mm wide simulating crack fabricated in the bottom plate was detected by scanning damper on the surface the top plate. With these results, it seems to be evident this measurement is capable of detecting delamination and cracks.

Fig. 2. Amplitude variation of the signal with phase velocity 4.35 x 10 3
mm/ms at 1.8 MHz.
When the damper was moved
from double plate area to single plate area, signal
level decreased as shown. To the right of the vertical
line segment is the single plate area. The decrease at
distance smaller than 30 mm is due to the mounting
effect of transmitter.

Fig. 3. Amplitude variation of the signal with phase velocity
4.35 x 10 3 m/sec at 1.8 MHz.as a function of distance
from transmitter to the damper. Inside each pair of
vertical line segments is the region where plates are
unbonded.
The parameter measured is the amplitude of ultrasonic signal as a function of distance. Therefore, if the only concern in the measurement is to find and locate the flaws, the scanning speed can be fast. In the above case, changes of amplitude responding to the disbonds are so that it took less than 20 seconds to scan a 35 cm distance found the three unbonded areas. However, the degree of variation of amplitude is a function of the width of area, that means, inspection rate should be slowed down for flaws of smaller dimensions. If a third acoustic transducer placed on the other side of the transmitter but on the same plate surface, the inspection area is then doubled.
symmetrical mode
|
and antisymmetrical mode
![]() |
2 Vs , which is approximately 4.4 x 103
m/sec for aluminum. Technically, longitudinal wave transducer drives the out-of-
plate displacement (Do) in Do/Di.
Due to the value of Do/Di tends to be
infinity when V =
2 Vs , and the limited input power to the transducer makes Do finite, the value of Di could then be small or even too small to propagate a Lamb wave. On the other hand, under the same conditions, with the same reasoning,
shear wave transducer excites the in-plate displacement (D i ), which would make the out-of-plate displacement Do as large as it can, and that is what we obtained in the experiments. The resultant relatively large value of Do makes the signal easily measurable in a long distance.
The purpose of applying an acoustic damper on the plate surface is to locally change the boundary conditions at the contact area of the damper with the test plate, which in changes the local loading condition of the plate. The of the particle displacements to this loading at the bonded area differs from that at the unbonded area, which results the quantitative difference in the change of the received signal levels. Since the response occurs immediately after contact, the optimum scanning rate of the acoustic damper is determined by the rate of the measurement of amplitude.
It is not clear at this moment that what is the main mechanism causing the different responses to loading by and unbonded areas. One possible interpretation is that the structural flaws, which are disbonds or cracks in this case, reduces the thickness of test sample in their locations, and act as wave scattering centers. Accompanying with the wave conversions occurred at the boundary of scattering center, scattering effect results in a different wave energy distribution from that of a flaw free sample or a flaw free portion in the same sample. The acoustic damper functions as probe to map the variation of this energy distribution. To prove this suggested model, understanding of energy distribution of wave modes in plate becomes necessary. Measurements on various geometries of plate assemblies are undergoing, which may provide further information of sound waves propagating in a plate configuration.
As to the application to large area integrity inspection, this measurement has several advantages for the future development; In this measurement, the transducers are at positions for each inspected area which can easily span more than 60 cm in length, and thus reduce the effects of variations between transducer and test specimen surface, encountered in the other ultrasonic inspection techniques. matter of fact, as long as the requirements for generating plate waves described in the previous paragraphs are met, method for generating waves is not essential to the measurement. It is possible to employ other non-contact techniques, such as optical and magnetic means, to excite detect the expected mechanical waves. Furthermore, in order extend the physical dimension of inspection, three linear arrays of transducers: one as transmitters and the others as receivers, can be arranged to produce and receive parallel beams of plate waves; In this case, by using comparison the occurrence of structural flaws may be determined, and a long acoustic damper can be used to scan and find the flaw location.
In summary, guided plate waves are able to interact with structural flaws such as delaminations and cracks due to propagation properties highly sensitive to the thickness in materials. A technique which employs an acoustic damper probe the results of this interaction and then to locate in a relatively short period of time is developed. With its technical advantages, this technique shows its potential application to large area structural integrity assessment.
Refer also to Article
"
Disbond Detection in Bonded Aluminum Joints Using Lamb Wave Amplitude and Time-Of Flight"
Download Postscrip Version
20th Review of Progress in Quantitative Nondestructive Evaluation Brunswick, Maine, USA August 1-6, 1993, pp. 1507-1513.
Abstract:
For testing the capability of disbond detection of plate wave, low
order modes of Lamb waves were generated and propagated across
aluminum lap splice joints fabricated with various geometry of
disbond. Specimens include joints bonded with different types of
adhesive and built with and with out rivet rows. Amplitude as well as
time-of-flight of transmitted waves were monitored while they were
scanned parallel to the long dimension of a lap joint. It was
observed that both these propagation properties were affected when
wavescontinued their propagation through areas with disbond, and thus
provided an approach, which locates disbonds by data comparison. Mode
conversion from one symmetry to another was believed to occur at
disbond and contributed to the changes of propagation properties.
Results of the measurement are presented and compared with those
obtained with standard ultrasonic c-scan.
NASA Langley Technical Report Server (LTRS).
| | UTonline | |Top | |