![]() ·Table of Contents ·General | The non-destructive testing in an industry with use of rhe radionuclidesV. Ivanov, N. Kuzelev, V. Gratchov, E. Zhukovsky, L. Kosarev.Contact |
| Diameter of the tested objects | 5-250 mm |
| Time of information collection | 1-5 min |
| Time of computer processing | 30-40 s |
| Minimal size of the details detected in the object in percents to its total volume | 0.1 |
| Maximal number of elements of the picture in the screen of the monitor | 512´512 |
Fig 4:
|
Fig 5:
|
Fig 6:
|
Container (4 canals) tip
|
Exposure head tip
|
| Gamma-radiation source, isotope | Se-75 | |||
| T1/2 | » 120 days | |||
| Eg, MeV (activity, Ci) | »0,215(120) | |||
| Active core size, mm Se-75 | To Ø 3x3 | |||
| Thickness of material exposure (Fe), mm. | 5-30 | |||
| Displacement of the radiation source, m -horizontally -vertically | To 8,0 To 4,0 | |||
| Transportation and recharging | Container (4 channals) | |||
| Working temperature, Co | From - 50 to +50 | |||
| Service life | to 5 year or 50000 cycles | |||
| Gamma-radiation exposure dose capacity with the radiation source recommended for the given apparatus. On surface of the exposure head At 1-m distance from the exposure container surface with radiation source inside | (position storage, not more) 0,56(200) Micro Sv/s (m ram/h) 0,0056(2) Micro Sv/s (m ram/h) | |||
| Overall dimensions of the, mm - - exposure head - -hand management (unfold) | 224x100x175 8200x60x120 | |||
| Mass, kg -exposure head. -hand management (unfold) | »20 »8 | |||
Fig 1: TECHNICA1 DATA -Se4/P
| ||||
|
| Gamma-radiation source, isotope | Co-60 | |||
| T1/2 | 5,25 years | |||
| Eg, MeV (activity, Ci) | 1,25 (100) | |||
| Active core size, mm Co-60 | To Ø 4x4 | |||
| Thickness of material exposure (Fe), mm. | 30 - 200 | |||
| Displacement of the radiation source, m -horizontally -vertically | To 8,0 To 4,0 | |||
| Transportation and recharging | Container (2 channals) | |||
| Working temperature, C° | From +1,0 to +45 | |||
| Service life | to 8 years or 50000 cycles | |||
| Gamma-radiation exposure dose capacity with the radiation source recommended for the given apparatus. On surface of the exposure head At I-m distance from the exposure container surface with radiation source inside | (position storage, not more) 0,56(200) Micro Sv/s (m ram/h) 0,0138(5) Micro Sv/s (m ram/h) | |||
| Overall dimensions of the, mm - exposure head - container (2 channals) - hand management (unfold) | 450x270x320 Ø 300x350 8200x60x120 | |||
| Mass, kg - exposure head. - container (2 canals) - hand management (unfold) | »152 »150 »8 | |||
| electrical management | 220 V, 50Hz, 500 VA | |||
Fig 2: TECHNICA1 DATA -K/100 | ||||
| Gamma-radiation source, isotope | Se-75, Ir-192 | |||
| T1/2 Se-75 T1/2 Ir-192 | »120 day »74 day | |||
| Eg, MeV (activity, to Ci) Se-75 Ir-192 | »0,215(120) »0,400 (120) | |||
| Active core size, mm Se-75 . Ir-192 | To Ø 3x3 To Ø 4x4 | |||
| Thickness of material exposure (Fe), mm. Se-75 Ir-192 | 5-30 10-60 | |||
| Transportation and recharging | Container (4 channals) | |||
| Overall dimensions of the, mm - exposure head | 300x130x270 | |||
| Mass, kg - exposure head. | »20 | |||
Fig 3: TECHNICA1 DATA ![]() | ||||
| © AIPnD , created by NDT.net | |Home| |Top| |