Q Net Quality Management GmbH Altenkesseler Str. 17 B5 D-66115 Saarbrücken Germany |
| Phone: +49-681-976 71 53 Fax: +49-681-976 71 58 Email: Q-NET@t-online.de
![]() |
|
|
| Ultrasonic Components | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| PC System | 4 transmit/receive channels per module, expandable to 4 more
transmit/receive channels for a total of 8 transmit/receive channels (optional modules) Rack-mount System | 4 transmit/receive channels per module, expandable a total of 64
| transmit/receive channels (optional modules, 4 channels each) Options | ½ size analog board with 4 channels and full size analog board with 8
| channels Transmitter Pulse | Needle pulse
| Transmitter Voltage | 50, 100, 150, 200, 250 Vpp ; for one individual scan cycle
| Transmitter Output Impedance | 50 Ohm
| Pulse Repetition Rate | < 5 kHz, dependent on selected sweep range and sampling rate,
| Input Dynamic | 97 dB with narrow-band filter 1MHz
| 85 dB with broad-band filter (0.3 – 15 MHz) Frequency Range (-3 dB) | 0.3 – 15 MHz
| Amp Characteristics (Receiver) | Linear, logarithmic (optional)
| Variable Amp/TGC | 40 dB, 0.2 dB resolution
| Pulse Mode | Pulse-Echo (P/E), Transmit/Receive (T/R)
| Analog Boards (4 Channels) | ½ size ISA (16 bit), 166mm x 127mm
| Digital Boards (2) | Full size ISA (16 bit), 332mm x 127mm, and ADC clip-on
| Data Processing
| A/D Converter | 1 ADC 10 bit (9 bit & header), 80 MS/sec
| 1 ADC 12 bit (11 bit & header), 40 MS/sec A/D Converter Dynamic | 54 dB for 10 bit ADC
| 66 dB for 12 bit ADC A/D Converter Rate | 80 MS/sec (10 bit ADC), 40 MS/sec, 20 MS/sec, 10 MS/sec, adjustable
| Standard A-scan data | Included
| Standard RF data | Included
| Half-wave peak data | Add-on board (optional)
| Pixelized A-scan data | Add-on board (optional)
| Gated data | Add-on board (optional)
| ALOK data | Peak Detector board (optional)
| Number of Scan Cycles | 256, individually programmable
| Maximum Cycle Rate | 1 kHz
| Scan Speed | Dependent on internal bus clock (20 MHz), Cycle processing delay (30
| msec) and Processing time (min. 170 msec) Data Acquisition Rate | 480 Kbytes/sec, on-line display of 4 A-scans and writing to HDD
| simultaneously (60 MHz Pentium processor) Scan Cycle | Triggering Position, time, manual, external
| 128 programmed scan trigger functions can be activated/deactivated Interfaces
| DSP Interface | Add-on DSP board (optional) for special processing
| Phased-Array Interface | Analog included
| Digital (optional) Programmable from PC (PCUS 40) EMAT Phased-Array Interface | Analog included
| Programmable from PC (PCUS 40) Eddy Current Interface | Digital (optional)
| Programmable from PC (PCUS 40) User Interface/Menus | Controllable from PC (PCUS 40)
| System Configurations | · Maximum of 8 Channels
| Portable System (Laptop PC) | · Keyboard and/or touch screen (optional) operation
| · TFT color monitor · Protection class up to IP54 (optional) Desktop/Tower PC | · Maximum of 64 Channels
| · Protection class up to IP54 (optional) Industrial PC | · Maximum of 64 Channels
| · Protection class IP54 19” Rack System | · Maximum of 64 Channels
| · Passive backplane Protection class IP65 · High-speed data interface · Protection class IP65 Operating Temperature | -5°C to 50°C (23°F to 122°F)
| Storage Temperature | -40°C to 70°C (-40°F to 158°F)
| Software CPS-N
| Operating System | Windows NT
| Menus | Inspection Parameter for:
| · component data, scan setup data, global data (date & time, · databank for component, setup, etc., history data On-line Display | A-scan and C-scan presentation of maximum 4 selections simultaneously
| Off-line Display | A-scan, Composite A-scan, C-scan, Composite BCD-scan, Zoom
| functions, various measuring selections, SAFT reconstruction (optional) | ||
SPECIAL MAY '98 EXHIBITION|
| NDTnet Exhibition |
|Index of Exhibitors| |Index of Showcases| | NDTnet | |