where expertise comes together since 1996

The Web's Largest Open Access Database of Nondestructive Testing (NDT) ISSN 1435-4934
Conference Proceedings, Articles, News, Exhibition, Forum and a Professional Network

Keyword: Radiographic Testing (RT),
Search Results: 1380
172 Exhibitors' Articles
Applus RTD.. 5
Applus RTD Insp.. 1
Dürr NDT GmbH C.. 2
Eclipse Scienti.. 1
EXTENDE.. 3
FORCE Technolog.. 2
GE Inspection T.. 18
GE Measurement.. 1
GE Measurement.. 1
GE Sensing & In.. 8
GE Sensing & In.. 4
GE Sensing & In.. 3
GE Sensing & In.. 1
GE Sensing & In.. 8
GE Sensing & In.. 1
GE Sensing & In.. 1
Hamamatsu Photo.. 6
intelligeNDT Sy.. 2
Materials Resea.. 1
NDT.net.. 1
Olympus.. 1
Olympus-Innov-X.. 1
Tecnatom S.A... 1
TWI Ltd (The We.. 7
Ultrasound Inst.. 4
Volume Graphics.. 8
X-RAY WorX GmbH.. 6
YXLON Internati.. 74
File Title / Author(s) / Keywords Publication Date


Neutron Tomography Measurement of Delayed Ettringite Formation in Concrete

R. Livingston15, S. Feuze1, A. Amde12, D. Hussey2, D. Jacobson2
1aMagerials Science & Engineering bCivil Engineering Dept.; University of Maryland5, College Park, MD [USA]
2Physical Measurement Laboratory ; National Institute of Standards and Technology (NIST) 2, Gaithersburg, MD [USA]
Radiographic Testing (RT), hydrogen, ettringite, tomography, neutron, concrete
11
NDCM 2015
- NDE of Infrastructure
2015-09


Inner Defect Detection in Ceramic Matrix Composite Parts using 3D X-ray CT Image Registration

S. Kondo1, H. Suzuki15, Y. Ohtake15, Y. Nagai12, H. Hishida22, K. Inagaki23, T. Nakamura22, F. Watanabe2
1University of Tokyo36, Tokyo [Japan]
2Ishikawajima-Harima Heavy Industries Co. (IHI Corporation)4, Tokyo [Japan]
Radiographic Testing (RT), defect detection, ceramic matrix composites, X-ray CT, non-destructive inspection, meandering
32
DIR 2015
- Defect detection
2015-08


Improvement of radiography images contrast and detection of the cracks in welds by dehazing algorithm

A. Movafeghi16, E. Yahaghi23, N. Mohammadzadeh14, B. Rokrok15, N. Rastkhah18
1Nuclear Safety and Radiation Protection Technological Centre of Iran (INRA)11, Tehran [Iran]
2Imam Khomeini International University3, Ghazvin [Iran]
defect detection, Modelling, image processing, Radiographic Testing (RT), Radiographic Testing (RT), Defect detection, image processing, Modelling
33
DIR 2015
- Defect detection
2015-08


Recent Requirements for Digital Radiography Substituting Film in Different Industries and Standard Organizations

U. Zscherpel92, U. Ewert194
BAM Federal Institute for Materials Research and Testing1024, Berlin [Germany]
Radiographic Testing (RT), standardisation, digital detectors, film replacement, basic spatial resolution, contrast sensitivity, ndt, unsharpness, X-ray, Standards, Qualification and system reliability, radiographic procedures
45
DIR 2015
- Keynote
2015-08



Multi-Lateral Shearing Interferometry: Principle and Application on X-ray Laboratory Sources

A. Stolidi1, D. Tisseur18, J. Primot2
1Commissariat Energie Atomique (CEA)175, Gif-Sur-Yvette [France]
2ONERA2, Palaiseau [France]
Modelling, Phase contrast, image processing, Radiographic Testing (RT), Radiographic Testing (RT), Modelling, Phase contrast, Image processing
32
DIR 2015
- Modelling
2015-08


Computed Radiography System Simulation Focusing on the Optical Readout Process

V. Kaftandjian123, M. Yao13, P. Duvauchelle112, A. Peterzol-Parmentier23, A. Schumm320, P. Willems43
1National Institute of Applied Science ( INSA-Lyon)- University of Lyon46, Villeurbanne [France]
2AREVA NDE-Solutions3, Chalon-sur-Saone [France]
3Electricité de France (EDF) R&D 26, Clamart [France]
4GE Sensing & Inspection Technologies11, Berchem [Belgium]
X-ray detectors and sources, Modelling, Radiographic Testing (RT), Radiographic Testing (RT), Modelling, X-ray detectors and sources, Computed radiography modelling, Optical readout
32
DIR 2015
- Modelling
2015-08


Properties and Application Areas of Photon Counting and Energy Resolving Digital Detector Arrays

U. Zscherpel192, D. Walter13, U. Ewert1194, C. Ullberg22, N. Weber22, T. Pantsar32, K. Perez-fuster3
1BAM Federal Institute for Materials Research and Testing1024, Berlin [Germany]
2XCounter AB2, Danderyd [Sweden]
3Ajat OY Ltd6, Espoo [Finland]
X-ray detectors and sources, Photon counting, Multi-energy, Radiographic Testing (RT), Digital detector, direct detection, energy resolution, scatter reduction, dual-energy
18
DIR 2015
- Multi-Energy imaging
2015-08


Enhancing X-ray imaging of liquids in porous materials

R. Kaufmann16, F. YANG1, F. Prade2, M. Griffa13, I. Jerjen111, C. Bella1, J. Herzen2, A. Sarapata2, F. Pfeiffer22, P. Lura1, A. NEELS1
1Empa, Swiss Federal Laboratories for Materials Science and Technology60, Dübendorf [Switzerland]
2Technical University of Munich (TUM)41, Munich [Germany]
CT, multi-angle radiography, Phase contrast, Radiographic Testing (RT), dark-field imaging, small angle scattering, porous materials, water
24
DIR 2015
- Phase Contrast Imaging
2015-08



Automated detection of artefacts for computed tomography in dimensional metrology

M. Fleßner, A. Müller2, E. Helmecke, T. Hausotte
University Erlangen-Nürnberg (FAU)23, Erlangen [Germany]
Radiographic Testing (RT), artefacts, Dimensional metrology, Computed Tomography, CT, Dimensional control, multi-angle radiography, surface point quality, surface point uncertainty
27
DIR 2015
- Poster
2015-08


X-ray investigation of the consolidation treatment

I. Jandejsek4, Z. Slížková, K. Niedoba
Czech Technical University (CVUT)58, Prague [Czech Republic]
image processing, Radiographic Testing (RT), consolidation, limestone
12
DIR 2015
- Poster
2015-08



Radiography simulation with aRTist – combining analytical and Monte-Carlo methods

C. Bellon38, A. Deresch18, G. Jaenisch28
BAM Federal Institute for Materials Research and Testing1024, Berlin [Germany]
CT, multi-angle radiography, Modelling, laminography, Radiographic Testing (RT),
34
DIR 2015
- Poster
2015-08


Application of micro-CT testing in the analysis of the silicate matrix composites

I. Kumpova14, T. Fila13, D. Vavrik18, I. Jandejsek14, Z. Kersner2
1Czech Technical University (CVUT)58, Prague [Czech Republic]
2Brno University of Technology (BUT)201, Brno [Czech Republic]
Radiographic Testing (RT), defect detection, CT, multi-angle radiography, RTG micro-CT, dynamic defectoscopy, silicate matrix composites
14
DIR 2015
- Poster
2015-08


Hundreds of Megapixels Radiography, from Micro to Macro Scale

D. Vavrik18, J. Jakubek14, J. Uher1, J. Lauterkranc
1Czech Technical University (CVUT)58, Prague [Czech Republic]
X-ray detectors and sources, Photon counting, Multi-energy, defect detection, image processing, Radiographic Testing (RT), Large area radiography, High resolution, Single photon counting detector
9
DIR 2015
- Poster
2015-08


Computed Radiography Systems for Radiographic Testing of Commercial Aircrafts

A. Movafeghi16, E. Yahaghi23, N. Mohammadzadeh14, B. Rokrok15, N. Rastkhah18
1Nuclear Safety and Radiation Protection Technological Centre of Iran (INRA)11, Tehran [Iran]
2Imam Khomeini International University3, Ghazvin [Iran]
defect detection, image processing, film replacement, Radiographic Testing (RT), Radiographic Testing (RT), Defect detection, Film replacement, image processing
21
DIR 2015
- Poster
2015-08



Inspection of welded object based on the shape from shading image processing method

A. Movafeghi16, E. Yahaghi23, N. Mohammadzadeh14, B. Rokrok15, N. Rastkhah18
1Nuclear Safety and Radiation Protection Technological Centre of Iran (INRA)11, Tehran [Iran]
2Imam Khomeini International University3, Ghazvin [Iran]
defect detection, Modelling, image processing, Radiographic Testing (RT), image processing, Defect detection, Radiographic Testing (RT), Modelling
33
DIR 2015
- Poster
2015-08


Inspecting Cast Materials using High Energy Digital Radiography

D. Oliveira111, A. Machado13, A. Silva13, J. Nascimento12, C. Gomes1, H. SIMÕES2, R. Lopes113
1Federal University of Rio de Janeiro (UFRJ)40, Rio de Janeiro [Brazil]
2TENARIS-CONFAB Industrial S.A.2, Pindamonhangaba / São Paulo [Brazil]
image processing, film replacement, Radiographic Testing (RT), Digital Radiography, Cast Inspection, High Energy, Image Processing
16
DIR 2015
- Quantitative imaging and image processin...
2015-08


Flat Panel Detectors: a Possibility for Film Replacement in High Energy NDT Applications

A. Peterzol-Parmentier13, O. Burat15, J. Banchet23
1AREVA NDE-Solutions3, Chalon-sur-Saone [France]
2AREVA NP3, Lyon [France]
X-ray detectors and sources, film replacement, standardisation, Radiographic Testing (RT), digital radiography, FPD, gamma sources, linear accelerator, image quality
18
DIR 2015
- Quantitative imaging and image processin...
2015-08


High-resolution X-ray Backscatter Technique for Nondestructive Imaging of Aerospace Components

S. Kolkoori14, N. Wrobel20, U. Zscherpel92, U. Ewert194
BAM Federal Institute for Materials Research and Testing1024, Berlin [Germany]
Quantitative imaging, defect detection, Scattering, Radiographic Testing (RT), Aerospace applications, Digital radiography, X-ray backscatter imaging, NDT, CFRP components
23
DIR 2015
- Quantitative imaging and image processin...
2015-08


Refinement of Imaging Processing of Scatter Correction and Beam Hardening Tools for Industrial Radiography and Cone Beam CT

D. Shedlock1, A. WANG1, D. Nisius2, M. Hu2, S. YOON1, A. Brooks2, E. Shapirro1, J. Star-lack1
1Varian Medical System, Palo Alto, CA [USA]
2Varian Medical Systems, Lincolnshire, IL [USA]
CT, multi-angle radiography, Scattering, image processing, Radiographic Testing (RT), Scatter correction, beam hardening, high energy, resolution, enhancement, processing, cone beam, CT
16
DIR 2015
- Quantitative imaging and image processin...
2015-08



3D reconstructions from bulky objects using sparse-angle data

J. Huhtamäki1, J. Toivola1, S. Wronka22, W. Dziewiecki22
1Eigenor Corporation, Helsinki [Finland]
2National Centre for Nuclear Research (NCBJ)3, Otwock [Poland]
CT, multi-angle radiography, X-ray detectors and sources, defect detection, film replacement, Radiographic Testing (RT), LINAC, sparse-angle measurement, 3D reconstruction, X-ray CT, statistical inversion
Appendix: 75_Huhtamaki_Rev1.avi 2.3 MB Movie projection images of a petrol engine - 75_Huhtamaki_Rev2.avi 1.6 MB Movie projection images of a solid-fuel rocket - 75_Huhtamaki.mp4 1.6 MB Movie projection images of a thyratron -
31
DIR 2015
- Reconstruction methods
2015-08
 
Page:
 -1-   2   3   4   5   6   7   8   9   10   11   12   13   14   15   16   17   18   19   20   21   22   23   24   25   26   27   28   29   30   31   32   33   34   35   36   37   38   39   40   41   42   43   44   45   46   47   48   49   50   51   52   53   54   55   56   57   58   59   60   61   62   63   64   65   66   67   68   69 
next pageNext
Call For Papers or Coming Soon Events

© NDT.net   |Advertise|   |Contact|   |About Us