where expertise comes together - since 1996

Web's Largest Portal of Nondestructive Testing (NDT)
Open Access Database (Conference Proceedings, Articles, News), Exhibition, Forum, Network

Search Results: 14

Languages
English (12)
German (2)

Title / Author(s) / Keywords Publication Date
Animated View for Detection of Hairline Fracture of the Cooling Hole of a Tornado Jet Turbine Blade by a CAD Based on the De-Convolution Technique.
K. Chui14, S. Zhang23, E. Lehmann314, A. Kaestner37, S. Chui4, D. Stanfield14, A. Wride14
1Image Enhancement Technology Ltd4, Uxbridge [United Kingdom]
2Rutherford Appleton Laboratory; Science and Technology Facilities Council3, Didcot [United Kingdom]
3Neutron Imaging and Activation Group, Laboratory for Neutron Scattering and Imaging; Paul Scherrer Institute23, Villigen [Switzerland]
4University Hospital of Northern British Columbia (UNBC)3, Prince George, BC [Canada]
Aviation

 
WCNDT 2016
Session: Aviation
2016-07
Combined neutron and X-ray imaging – imaging with a second opinion
A. Kaestner7, D. Mannes2, E. Lehmann14
Neutron Imaging and Activation Group, Laboratory for Neutron Scattering and Imaging; Paul Scherrer Institute23, Villigen [Switzerland]
Bimodal imaging, Neutrons, X-rays, Instrumentation, Applications

 
iCT 2016
Session: Multi-modal and multi-energy
2016-02
Bimodal Imaging Using Neutrons and X-rays
A. Kaestner7, M. Morgano, J. Hovind, E. Lehmann14
Laboratory for Neutron Scattering and Imaging; Paul Scherrer Institute23, Villigen [Switzerland]
Multi-techniques fusion, Other radiation techniques (neutron), CT, multi-angle radiography,

 
DIR 2015
Session: CT imaging
2015-08
Detections of Minute Defects and Accurate Measurements of Distance & Area of Objects in Neutron Beam Computed Tomography and X-ray Radiography Images by a CAD Based on the De-Convolution Technique
K. Chui14, S. Chui23, S. Zhang33, E. Lehmann414, A. Kaestner47, A. Wride14, D. Stanfield14
1Image Enhancement Technology Ltd4, Uxbridge [United Kingdom]
2University Hospital of Northern British Columbia (UNBC)3, Prince George, BC [Canada]
3Rutherford Appleton Laboratory; Science and Technology Facilities Council3, Didcot [United Kingdom]
4Spallation Neutron Source Division; Paul Scherrer Institute23, Villigen [Switzerland]
NDT-wide, Neutron Beam Computed Tomography, X-ray Radiography, Image Enhancement, De-Convolution Technique, Accurate Measurements

 
ECNDT 2014
Session: Signal and image processing in NDT/NDE
2014-12
Accurate Area and Width Measurements from Neutron Beam Computed Tomography (NBCT) Images of Cooling Holes of a Used Tornado Jet Engine Turbine Blade by a CAD Based on the De-Convolution Technique
K. Chui14, S. Zhang23, E. Lehmann314, A. Kaestner37, S. Chui43, A. Wride14, D. Stanfield14
1Image Enhancement Technology Ltd4, Uxbridge [United Kingdom]
2Rutherford Appleton Laboratory; Science and Technology Facilities Council3, Didcot [United Kingdom]
3Neutron Imaging and Activation Group; Paul Scherrer Institute23, Villigen [Switzerland]
4University Hospital of Northern British Columbia (UNBC)3, Prince George, BC [Canada]
NDT-wide, Radiographic Testing (RT), De-Convolution Technique, Neutron-Beam Computed Tomography, image enhancement, Computer aided detection, accurate measurements of area & distance, detection of fracture in jet turbine blade

 
AeroNDT 2013
Session: CT Applications
2013-12
Neutron Tomography as an Alternative Option for Non-Destructive Testing
C. Grünzweig3, E. Lehmann14, D. Mannes2
Neutron Imaging and Activation Group; Paul Scherrer Institute23, Villigen [Switzerland]
 
AeroNDT 2012
Session: Radiography
2013-02
Challenging non-destructive applications for neutron imaging
A. Kaestner7, C. Grünzweig3, E. Lehmann14
Neutron Imaging and Activation Group; Paul Scherrer Institute23, Villigen [Switzerland]
Radiographic Testing (RT), Other Methods, image processing, Computed Tomography, Neutron imaging

 
WCNDT 2012
Session: Neutron Radiography
2012-07
Scientific establishment of standardized practice for assessment of spatial resolution and contrast of international digital thermal neutron imaging facilities
M. Radebe13, F. De Beer15, E. Lehmann214, A. Kaester2, C. Sim32
1Nuclear Energy Corporation of South Africa (NECSA)8, Pretoria [South Africa]
2Paul Scherrer Institute23, Villigen [Switzerland]
3Korea Research Institute of Standards and Science (KRISS)63, Daejeon [South Korea]
Standard test phantoms, international digital thermal neutron imaging, good practice, spatial resolution, contrast

 
WCNDT 2012
Session: Neutron Radiography
2012-07
Neutronen-Tomographie als Option für die zerstörungsfreie Prüfung
C. Grünzweig3, E. Lehmann14, A. Kaestner7, P. Vontobel7, S. Hartmann3
Spallation Neutron Source Division; Paul Scherrer Institute23, Villigen [Switzerland]

 DE  
iCT 2010
Session: Alternative tomografische Verfahren
2011-06
Neue Erkenntnisse bei der Nutzung von Neutronenstrahlen für die Untersuchung industrierelevanter Komponenten
G. Frei3, E. Lehmann14
Paul Scherrer Institute23, Villigen [Switzerland]
Radiographic Testing (RT), neutron radiography, microtomography, aerospace, automotive, Public security
 DE  
DGZfP 2008
Session: Durchstrahlungsprüfung (RT)
2009-02
Neutron Imaging Facilities at the Paul Scherrer Institut and its Applications for Non-destructive Testing of Abrasive Water Jet Nozzle's
M. Bühlmann1, K. Heiniger1, B. Zweifel1, G. Frei23, G. Kühne2, E. Lehmann214, P. Vontobel27
1University of Applied Sciences in Northwestern Switzerland, Windisch [Switzerland]
2Paul Scherrer Institute23, Villigen [Switzerland]

 
ECNDT 2006
Session: Computed Tomography
2006-11
The inspection of tube fitting systems in use for drinking water supply by means of neutron imaging methods
D. Glauser1, H. Materna1, R. Widler1, G. Frei23, E. Lehmann2,214
1Geberit International AG, Jona [Switzerland]
2Paul Scherrer Institute23, Villigen [Switzerland]
Radiographic Testing (RT), neutron radiography, fitting systems, drinking water, detection of water

 
ECNDT 2006
Session: Public Security and Safety Technology
2006-11
Facilities for Neutron Radiography in Europe: Performance, Applications and future Use
E. Lehmann14
Paul Scherrer Institute23, Villigen [Switzerland]
Radiographic Testing (RT), neutron radiography

 
WCNDT 2000
Session: Neutron workshop
2000-11
Status and Prospects of neutron Tomography in Europe
W. Treimer16, T. Bücherl213, B. Schillinger27, P. Chirco3, S. Baechler4, J. Jolie4, R. Rosa5, M. Balasko65, A. Kuba6, H. Böck7, S. Körner72, S. Legoupil811, V. Micherov8, G. Bayon9, E. Lehmann1014, P. Vontobel107
1Technische Universität (TU) Berlin79, Berlin [Germany]
2Technical University of Munich (TUM)106, Munich [Germany]
3Physics Department; University of Bologna52, Bologna [Italy]
4University of Fribourg, Fribourg [Switzerland]
5ENEA Casaccia Research Center(CR)21, Casaccia [Italy]
6MTA KFKI Budapest5, Budapest [Hungary]
7Atominstitut Vienna2, Vienna [Austria]
8Lebedev Physics Institute Moscov2, Moscow [Russia]
9Commissariat Energie Atomique (CEA)278, Gif-Sur-Yvette [France]
10Paul Scherrer Institute23, Villigen [Switzerland]
Radiographic Testing (RT), neutron radiography

 
WCNDT 2000
Session: Neutron workshop
2000-11
   
Forthcoming Open Access Contributors

2018 Dec 19-21

2019 Feb 13-15

2019 Jun 17-21

SINCE 2019
2019 Dec 4-5

© NDT.net - The Web's Largest Portal of Nondestructive Testing (NDT) ISSN 1435-4934

Open Access Database, |Conference Proceedings| |Articles| |News| |Exhibition| |Forum| |Professional Network|