Search Results: 34
Title / Author(s) / Keywords PublicationDate
2018-08 ECNDT 2018, X-ray & CT modeling
X-ray detector for maximum efficiency in the energy range above 400keV - are 101dB worth the additional effort?
N. Felber, K. Bavendiek34, A. Deresch23
YXLON International GmbH184, Hamburg [Germany]
Detection systems, Image formation, Radiography, Research

 
ECNDT 2018
Session: X-ray & CT modeling
2018-08
2016-07 WCNDT 2016, Aviation
Radiographic Inspection - Film Replacement with Digital Detector Arrays in Aerospace Applications
F. Schulte1, K. Bavendiek234
1Alcoa Power and Propulsion TITAL GmbH, Bestwig [Germany]
2YXLON International GmbH184, Hamburg [Germany]
Aviation

 
WCNDT 2016
Session: Aviation
2016-07
2013-05 DGZfP 2012, Durchstrahlungsprüfung (RT) / Strahlenschutz
Effektive Brennfleck-Größen von Röntgenröhren bestimmen - neue Verfahren, Änderungen der Normen
K. Bavendiek134, U. Heike19, U. Ewert2212, U. Zscherpel2105, A. Riedo32
1YXLON International GmbH184, Hamburg [Germany]
2BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
3Comet AG5, Flamatt [Switzerland]
Radiographic Testing (RT)
 DE  
DGZfP 2012
Session: Durchstrahlungsprüfung (RT) / Strahlenschutz
2013-05
2012-07 WCNDT 2012, Radiography
New measurement methods of focal spot size and shape of X-ray tubes in digital radiological applications in comparison to current standards
K. Bavendiek134, U. Ewert2212, A. Riedo32, U. Heike19, U. Zscherpel2105
1YXLON International GmbH184, Hamburg [Germany]
2BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
3Comet AG5, Flamatt [Switzerland]
Radiographic Testing (RT), Non-destructive testing, Measurement, Radiography, Standards, X-ray tubes, focal spot sizes, magnification

 
WCNDT 2012
Session: Radiography
2012-07
2012-07 WCNDT 2012, Workshop on Advanced Digital Imaging
Digital reference image catalogues and image viewing
K. Bavendiek34, M. Kurfiss10
YXLON International GmbH184, Hamburg [Germany]
 
WCNDT 2012
Session: Workshop on Advanced Digital Imaging
2012-07
2012-07 WCNDT 2012, Workshop on Advanced Digital Imaging
High contrast sensitivity radiography with DDAs - how to exceed film quality?
P. Kramm5, K. Bavendiek34, M. Kurfiss10
YXLON International GmbH184, Hamburg [Germany]
 
WCNDT 2012
Session: Workshop on Advanced Digital Imaging
2012-07
2011-11 DIR 2011, 3D Reconstruction Algorithms
Geometric Corrections in Coplanar Translational Laminography
K. Thiessenhusen18, U. Ewert1212, B. Redmer161, K. Bavendiek234
1BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
2YXLON International GmbH184, Hamburg [Germany]
 
DIR 2011
Session: 3D Reconstruction Algorithms
2011-11
2011-11 DIR 2011, Qualification
Strategies for Film Replacement in Radiography - Approaches Used in the New Standards
U. Zscherpel1105, U. Ewert1212, M. Jechow118, K. Bavendiek234
1BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
2YXLON International GmbH184, Hamburg [Germany]
Radiographic Testing (RT), Digital Radiography, Digital Detector Arrays, x-ray image quality, digital imaging, Standardization
 
DIR 2011
Session: Qualification
2011-11
2011-01 DGZfP 2010, Durchstrahlungsprüfung (RT)
Ein neues Konzept zur Bestimmung der optimalen Röntgenspannung für die ZfP mit digitaler Radiographie
U. Ewert1212, K. Heyne12, U. Zscherpel1105, M. Jechow118, K. Bavendiek234
1BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
2YXLON International GmbH184, Hamburg [Germany]
Radiographic Testing (RT), filmless radiography, phosphor imaging plates, Digital Radiography, film replacement, flat-panel detector, Computed Radiography, contrast, image quality, Detectors, scattered radiation
 DE  
DGZfP 2010
Session: Durchstrahlungsprüfung (RT)
2011-01
2011-01 DGZfP 2010, Durchstrahlungsprüfung (RT)
Prüfung mit digitalen Detektoren (DDA) nach Norm - worauf kommt es an?
K. Bavendiek134, U. Ewert2212, U. Zscherpel2105
1YXLON International GmbH184, Hamburg [Germany]
2BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
Radiographic Testing (RT), film replacement, Resolution, Digital Detector Arrays, contrast, image quality, Detectors
 DE  
DGZfP 2010
Session: Durchstrahlungsprüfung (RT)
2011-01
2011-01 DGZfP 2010, Durchstrahlungsverfahren (RT) / Strahlenschutz
Veränderung der Röntgenprüfung durch Digitale Detektoren und Filtertechnik (HDR)
U. Adamczak2, K. Bavendiek34
YXLON International GmbH184, Hamburg [Germany]
 DE  
DGZfP 2010
Session: Durchstrahlungsverfahren (RT) / Strahlenschutz
2011-01
2010-08 ECNDT 2010, Computed Tomography
Gantry Gate Based X-Ray Computed Tomography in Aerospace Industry
B. Redmer161, U. Ewert1212, C. Rädel111, U. Schnars29, R. Henrich213, O. Schimmelmann22, K. Bavendiek334, M. Jahn33
1BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
2Airbus Operations GmbH66, Bremen [Germany]
3YXLON International GmbH184, Hamburg [Germany]
 
ECNDT 2010
Session: Computed Tomography
2010-08
2010-02 DGZfP 2009, Durchstrahlungsverfahren (RT) / Strahlenschutz
HDR - Hoch Dynamik Radioskopie
K. Bavendiek34, U. Heike9
YXLON International GmbH184, Hamburg [Germany]

 DE  
DGZfP 2009
Session: Durchstrahlungsverfahren (RT) / Strahlenschutz
2010-02
2010-02 DGZfP 2009, Luftfahrt
Tomographische vor-Ort-Prüfung großer Komponenten aus Faserkompositen in der Luftfahrt
B. Redmer161, U. Schnars29, O. Schimmelmann22, U. Ewert1212, K. Bavendiek334, M. Jahn43
1BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
2Airbus Operations GmbH66, Bremen [Germany]
3YXLON International GmbH184, Hamburg [Germany]
4intelligeNDT Systems & Services GmbH & Co. KG94, Erlangen [Germany]
Radiographic Testing (RT), laminography, flat-panel detector, Digital Detector Arrays, aerospace, wing, flaw detection

 DE  
DGZfP 2009
Session: Luftfahrt
2010-02
2008-11 WCNDT 2008, Radiographic Testing & Computed Radiologic Testing
Strategies for Film Replacement in Radiography - Films and Digital Detectors in Comparison -
U. Ewert1212, U. Zscherpel1105, K. Bavendiek234
1BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
2YXLON International GmbH184, Hamburg [Germany]
Radiographic Testing (RT), filmless radiography, phosphor imaging plates, radiographic film, Digital Radiography, film replacement, flat-panel detector, Resolution, x-ray imaging, Digital Detector Arrays, Computed Radiography, contrast, x-ray image quality, scattered radiation, Classification, image acquisition, image analysis, imaging, Scattering, sensitivity, signature analysis
 
WCNDT 2008
Session: Radiographic Testing & Computed Radiologic Testing
2008-11
2008-08 DGZfP RT-2007, Radiographic Testing & Computed Radiologic Testing
Hochkontrastempfindlichkeits-Radiographie für Luftfahrtkomponenten
K. Bavendiek134, U. Heike19, U. Ewert2212, U. Zscherpel2105
1YXLON International GmbH184, Hamburg [Germany]
2BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
Radiographic Testing (RT), computed tomography (CT), filmless radiography, laminography, microfocus x-ray, radiographic film, 3D Computed Tomography, Digital Radiography, film replacement, flat-panel detector, Resolution, Digital Detector Arrays, contrast, x-ray image quality, imaging, noise, aerospace, composite, carbon fiber reinforced plastic (CFRP), honeycomb, Lightweight Materials, delamination, quality assurance, ASTM
 DE  
DGZfP RT-2007
2008-08
2008-06 ZfP-Zeitung, Radiographic Testing & Computed Radiologic Testing
Die Grenzen der radiographischen Prüfung: Eine neue Hochkontrastempfindlichkeitstechnik Beispiele und systemtheoretische Analyse
K. Bavendiek134, U. Zscherpel2105
1YXLON International GmbH184, Hamburg [Germany]
2BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
Radiographic Testing (RT), filmless radiography, phosphor imaging plates, radiographic film, Digital Radiography, film replacement, flat-panel detector, Resolution, x-ray imaging, Digital Detector Arrays, Computed Radiography, x-ray image quality, Classification, image analysis, imaging, noise
 DE  
ZfP-Zeitung
2008-06
2007-11 PANNDT 2007, Radiography
Strategies for Film Replacement in Radiography - a comparative study -
U. Ewert1212, U. Zscherpel1105, K. Bavendiek234
1BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
2YXLON International GmbH184, Hamburg [Germany]
Radiographic Testing (RT), filmless radiography, phosphor imaging plates, radiographic film, Digital Radiology, Digital Radiography, film replacement, flat-panel detector, x-ray imaging, Digital Detector Arrays, Computed Radiography, contrast, x-ray image quality, signal, image analysis, image processing, imaging, noise, ASME, ASTM, EN
 
PANNDT 2007
Session: Radiography
2007-11
2007-10 DIR 2007, Introductive Session
Possibilities and limits of digital radiology
U. Zscherpel1105, U. Ewert1212, K. Bavendiek234
1BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
2YXLON International GmbH184, Hamburg [Germany]
Radiographic Testing (RT), radiographic film, digital radiology, film replacement, digital detector arrays, high contrast sensitivity technique, NDT film systems, Computed Radiography (CR) with imaging plates, image quality, basic spatial resolution, signal/noise ratio, contrast sensitivity
 
DIR 2007
Session: Introductive Session
2007-10
2007-08 ImagingNDE 2007, Digital Detection Technology
Digital Detector Arrays (DDA)
K. Bavendiek134, U. Ewert2212
1YXLON International GmbH184, Hamburg [Germany]
2BAM Federal Institute for Materials Research and Testing1266, Berlin [Germany]
Radiographic Testing (RT), Digital Radiography, digital detector arrays, x-ray image quality
 