where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)

Conference Proceedings, Articles, News, Exhibition, Forum, Network and more

where expertise comes together
- since 1996 -
Search Results: 25
Filter Results ...
Publications
iCT 2014 (2)
ECNDT 2014 (2)
iCT 2017 (2)
NDT Review (2)
DIR 2019 (2)
DIR 2011 (2)
iCT 2012 (2)
DIR 2015 (1)
iCT 2016 (1)
WCNDT 2016 (1)
iCT 2018 (1)
ECNDT 2018 (1)
ECNDT 2006 (1)
iCT 2019 (1)
DGZfP 2008 (1)
ECNDT 2010 (1)
DGZfP 2010 (1)
iCT 2010 (1)

Languages
English (22)
German (3)

Title / Author(s) / Keywords PublicationDate
2019-11 DIR 2019 Defect Detection & Localisation
At-line X-ray computed tomography of serial parts optimized by numerical simulations
M. Reiter125, C. Gusenbauer232, R. Huemer2, J. Kastner1120
1Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2Nemak Linz GmbH2, Linz, Austria

DIR 2019
Session: Defect Detection & Localisation
2019-11
2019-11 DIR 2019 Radiation Techniques
Improved Visualization of Polymer Foams using Talbot-Lau Grating Interferometry to Reduce Metal Artifacts
J. Glinz5, S. Senck21, M. Reiter25, A. Schrempf2, D. Fürst2, J. Kastner120
Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria

DIR 2019
Session: Radiation Techniques
2019-11
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
Porosity determination in additively manufactured Ti parts using X-ray tomography
J. Glinz5, M. Reiter25, T. Gastinger2, A. Huskic2, B. Plank47, J. Kastner120, S. Senck21
Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
X-ray micro-computed tomography, Additive manufacturing, Titanium alloys, Porosity determination, Microstructure

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-02 NDT Review Journal of Nondestructive Evaluation (Springer)
Porosity Determination of Carbon and Glass Fibre Reinforced Polymers Using Phase-Contrast Imaging
C. Gusenbauer32, M. Reiter25, B. Plank47, D. Salaberger38, S. Senck21, J. Kastner120
aSchool of Engineering bR&D Competence Center cSchool of Engineering and Environmental Sciences cReserach group computed tomography cResearch Group Computed Tomography; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
X-ray computed tomography, Talbot-Lau grating interferometer, Differential phase contrast, Carbon and glass fibre reinforced polymers, Porosity

NDT Review
Session: Journal of Nondestructive Evaluation (Springer)
2019-02
2019-02 NDT Review Journal of Nondestructive Evaluation (Springer)
Case Study of Empirical Beam Hardening Correction Methods for Dimensional X-ray Computed Tomography Using a Dedicated Multi-material Reference Standard
M. Reiter125, F. De Oliveira22, M. Bartscher233, C. Gusenbauer132, J. Kastner1,1120
1aR&D Competence Center bSchool of Engineering cResearch Group Computed Tomography; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2Physikalisch-Technische Bundesanstalt (PTB)44, Braunschweig, Germany
Industrial computed tomography, Dimensional metrology, Multi-material measurements, Beam hardening correction, Material influence

NDT Review
Session: Journal of Nondestructive Evaluation (Springer)
2019-02
2018-08 ECNDT 2018 CT-Applications
High-resolution X-ray computed tomography of inhomogeneous materials
C. Gusenbauer32, M. Reiter25, D. Salaberger38, B. Plank47, J. Kastner120
aSchool of Engineering bR&D Competence Center cReserach group computed tomography cSchool of Engineering and Environmental Sciences; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
Tomography

ECNDT 2018
Session: CT-Applications
2018-08
2018-02 iCT 2018 Poster exhibition
Simulation-based optimization of nano-XCT scans for high-resolution applications
C. Gusenbauer32, M. Reiter25, D. Salaberger38, J. Kastner120
aR&D Competence Center bReserach group computed tomography cResearch Group Computed Tomography; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
X-ray computed tomography, high-resolution, XCT simulation, materials characterization

iCT 2018
Session: Poster exhibition
2018-02
2017-03 iCT 2017 Materials Characterization
Multi-modal Talbot-Lau grating interferometer data for the characterization of fibre reinforced polymers with metal components
C. Gusenbauer132, M. Reiter125, B. Plank147, S. Senck121, C. Hannesschläger15, S. Renner2, R. Kaufmann39, J. Kastner1120
1Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2Fischer Advanced Composite Components (FACC)15, Ried, Austria
3Empa, Swiss Federal Laboratories for Materials Science and Technology77, Dübendorf, Switzerland
materials characterization, Computed Tomography, Phase contrast, carbon fibre reinforced polymers, Talbot-Lau XCT, grating interferometer, multi-modal, metal artefacts

iCT 2017
Session: Materials Characterization
2017-03
2017-03 iCT 2017 Poster
Distance measurements on inaccessible wires in plastic parts with X-ray computed tomography
M. Reiter125, C. Gusenbauer132, J. Kastner1120, G. Schmee2
1Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2Delphi Automotive Systems Austria GmbH, Mattighofen, Austria
Measurement Uncertainty, Dimensional metrology, Computed Tomography, XCT simulation, test process suitability, metrology, wire distance measurement, traceability

iCT 2017
Session: Poster
2017-03
2016-07 WCNDT 2016 Modelling and Data Processing
Comparison of Metal Artefact Reduction Algorithms from Medicine Applied to Industrial XCT Applications
C. Gusenbauer32, M. Reiter25, D. Salaberger38, J. Kastner120
R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
Modelling and Data Processing

WCNDT 2016
Session: Modelling and Data Processing
2016-07
2016-02 iCT 2016 Poster exhibition
SimCT: a simulation tool for X-ray imaging
M. Reiter125, M. Erler24, C. Kuhn213, C. Gusenbauer132, J. Kastner1120
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2 ; Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
Radiographic Testing (RT), x-ray imaging, Computed Tomography, Modelling, Radiography, simulation tool, X-ray interactions

iCT 2016
Session: Poster exhibition
2016-02
2015-08 DIR 2015 Qualification and system reliability
Measurement uncertainty evaluation of an X-ray computed tomography system
C. Gusenbauer32, M. Reiter25, J. Kastner120
Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
Dimensional control, Qualification and system reliability, CT, multi-angle radiography, VDI/VDE 2630-2.1, measurement uncertainty, X-ray computed tomography, metrology

DIR 2015
Session: Qualification and system reliability
2015-08
2014-12 ECNDT 2014 Computed Tomography
Automatic determination of optimal CT measuring parameters for an unknown part
C. Kuhn113, M. Reiter225, S. Schröpfer310, S. Kasperl338, D. Weiß112, M. Erler14
1 ; Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
2R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
3Development Center X-ray technology (EZRT); Fraunhofer Institute for Integrated Circuits (IIS)184, Fürth, Germany
computed tomography (CT), image quality measure, automatic parameter determination, parameter optimization, Software tool, CT Wizard

ECNDT 2014
Session: Computed Tomography
2014-12
2014-12 ECNDT 2014 Computed Tomography
Detection of non-metallic inclusions in steel by X-ray computed tomography and after fatigue testing
C. Gusenbauer132, M. Reiter125, J. Kastner1120, G. Kloesch2
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2voestalpine Stahl Donawitz GmbH2, Leoben, Austria
computed tomography (CT), steel plant, materials characterization, micro-structure characterization, steel, fatigue testing

ECNDT 2014
Session: Computed Tomography
2014-12
2014-06 iCT 2014 Algorithms and Special Issues
Evaluation of a Histogram-based Image Quality Measure for X-ray computed Tomography
M. Reiter125, D. Weiß212, C. Gusenbauer132, M. Erler24, C. Kuhn213, S. Kasperl338, J. Kastner1,1120
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2 ; Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
3Development Center X-ray technology (EZRT); Fraunhofer Institute for Integrated Circuits (IIS)184, Fürth, Germany
X-ray computed tomography, image quality measure, histogram

iCT 2014
Session: Algorithms and Special Issues
2014-06
2014-06 iCT 2014 Dimensional Measurement
Uncertainty in CT Metrology: Visualizations for Exploration and Analysis of Geometric Tolerances
A. Amirkhanov13, B. Fröhler16, M. Reiter125, J. Kastner1120, M. Grӧller2, C. Heinzl138
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2Institute of Computer Graphics and Algorithms; Vienna University of Technolog (TU)57, Vienna, Austria
Industrial 3D computed tomography, uncertainty visualization, level-of-details, metrology

iCT 2014
Session: Dimensional Measurement
2014-06
2012-12 iCT 2012 Dimensional Measurement - Measurement Parameters
Evaluation of transmission based image quality optimisation for X-ray computed
M. Reiter125, S. Kasperl238, C. Kuhn313, M. Erler34, D. Weiß312, C. Heinzl138, C. Gusenbauer132, J. Kastner1120
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2Development Center X-ray technology (EZRT); Fraunhofer Institute for Integrated Circuits (IIS)184, Fürth, Germany
3 ; Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
Radiographic Testing (RT), parameter optimisation, X-ray computed tomography, transmission, optimised scan, EN 16016

iCT 2012
Session: Dimensional Measurement - Measurement Parameters
2012-12
2012-12 iCT 2012 Dimensional Measurement and Special Applications
Evaluation of Projection-Based Metal-Artifact Reduction for Multi-Material Components
A. Amirkhanov13, M. Reiter225, J. Kastner2120, E. Gröller111, C. Heinzl2,138
1Institute of Computer Graphics and Algorithms; Vienna University of Technolog (TU)57, Vienna, Austria
2R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
metal-artifacts reduction, multi-material components, 3DCT dimensional metrology

iCT 2012
Session: Dimensional Measurement and Special Applications
2012-12
2011-11 DIR 2011 Poster
Simulation Aided Study for Optimising Industrial X-ray CT Scan Parameters for Non-Destructive Testing and Materials Characterisation
M. Reiter125, C. Kuhn213, C. Gusenbauer132, B. Harrer113, C. Heinzl138, J. Kastner1120, D. Salaberger138
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2 ; Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
NDT-wide, Radiographic Testing (RT), computed tomography, Computed Tomography, Other Methods
DIR 2011
Session: Poster
2011-11
2011-11 DIR 2011 Poster
Fast Estimation of Optimal Specimen Placements in 3D X-ray Computed Tomography
C. Heinzl138, J. Kastner1120, A. Amirkhanov23, E. Gröller211, M. Reiter125
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2Institute of Computer Graphics and Algorithms; Vienna University of Technolog (TU)57, Vienna, Austria
3D X-ray computed tomography, Metal-artifact reduction, multi-material components, Other Methods
DIR 2011
Session: Poster
2011-11
 
Page:
 -1-   2 
next pageNext
Actual Cooperations
Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window