where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)

Conference Proceedings, Articles, News, Exhibition, Forum, Network and more

where expertise comes together
- since 1996 -

Archive Authors Keywords


Publication Index



Select filters or/and search


Sort Pages
Check Filters!
New/Updated
NDT.net Journal
NDT Review
NDE-Nuclear-2019
DGZfP MTHz 2019
DGZfP 2019
DGZfP AE-2019
NDE-India 2018
MMM-NDT 2019
more >
New/UpdatedNDT.net JournalNDT ReviewNDE-Nuclear-2019DGZfP MTHz 2019DGZfP 2019DGZfP AE-2019NDE-India 2018MMM-NDT 2019 more >

Keyword: microfocus x-ray,
Search Results: 65
Title / Author(s) / Keywords PublicationDate
2014-03 DGZfP 2013 Durchstrahlungsprüfung (RT) / Strahlenschutz
Messung von Brennfleckgrößen bei Mikrofokus Stabanodenröhren
J. Steffen10
X-RAY WorX GmbH16, Garbsen, Germany
Radiographic Testing (RT), microfocus x-ray, aerospace, heat exchanger, turbine, Digital Radiography, weld inspection, gas turbine, high resolution radiography
DE
DGZfP 2013
Session: Durchstrahlungsprüfung (RT) / Strahlenschutz
2014-03
2013-05 DGZfP 2012 Prozessüberwachung
Automatisches CT-System mit integrierter Auswertung
M. Maisl122, F. Porsch110, M. Rehak29, A. Gelz32
1aDevelopment Center for X-ray Technologies (EZRT) bDevelopment Center for X-ray technology (EZRT); Fraunhofer-Institute for Non-Destructive Testing (IZFP)474, Saarbrücken, Germany
2Development Center X-ray technology (EZRT); Fraunhofer Institute for Integrated Circuits (IIS)177, Fürth, Germany
3Q NET Engineering GmbH14, Saarbrücken, Germany
Radiographic Testing (RT), microfocus x-ray, Automated Inspection, quality control, seed, 3D image analysis, Computed Tomography, sugar beet, random sample
DE
DGZfP 2012
Session: Prozessüberwachung
2013-05
2013-05 DGZfP 2012 Radiographie
Die Anwendung hochauflösender Stabanodenröhren in der Schweißnahtprüfung mit Vergrößerung nach EN ISO 17636-2
J. Steffen10, T. Fröba7
X-RAY WorX GmbH16, Garbsen, Germany
Radiographic Testing (RT), microfocus x-ray, Digital Radiography, weld inspection
DE
DGZfP 2012
Session: Radiographie
2013-05
2012-05 DGZfP 2011 Durchstrahlungsprüfung (RT) / Strahlenschutz
Optimierung hochauflösender Stabanoden für denndustriellen Dauereinsatz
T. Fröba7, J. Steffen10
X-RAY WorX GmbH16, Garbsen, Germany
DE
DGZfP 2011
Session: Durchstrahlungsprüfung (RT) / Strahlenschutz
2012-05
2012-05 DGZfP 2011 Hersteller und Lieferanten von Prüfgeräten und Zubehör
Weiterentwicklung der Mikrofokus-Reflexionsröhre fürndustrielle Anwendungenn der Messtechnik
T. Fröba7, J. Steffen10
X-RAY WorX GmbH16, Garbsen, Germany
DE
DGZfP 2011
Session: Hersteller und Lieferanten von Prüfgeräten und Zubehör
2012-05
2011-11 DIR 2011 X-ray Sources
Reducing the Focal Spot Shift of Microfocus X-ray Tubes to Increase the Accuracy of CT-Based Dimensional Measurement
J. Steffen10, T. Fröba7
X-RAY WorX GmbH16, Garbsen, Germany
Radiographic Testing (RT), microfocus x-ray, Dimensional Measurement, micro-CT, Computed Tomography
DIR 2011
Session: X-ray Sources
2011-11
2011-06 iCT 2010 Einflüsse auf die CT-Messgenauigkeit
Einfluß der Quellbewegung auf Reproduzierbarkeit und Antastabweichung im Röntgen-Computertomographen
D. Weiß12, A. Deffner3, C. Kuhn13
Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
Radiographic Testing (RT), microfocus x-ray, Dimensional Measurement, Reproducibility, Computed Tomography, Cone beam computed tomography, X-ray source movement, probing error form, probing error size

DE
iCT 2010
Session: Einflüsse auf die CT-Messgenauigkeit
2011-06
2011-06 iCT 2008 Geometriebestimmung
Untersuchung der Genauigkeit schneller ?CT-Scans und deren Eignung für die industrielle Qualitätssicherung
J. Steffen10, G. Rademaker2
YXLON International GmbH194, Hamburg, Germany
Radiographic Testing (RT), microfocus x-ray, micro-CT, Computed Tomography

DE
iCT 2008
Session: Geometriebestimmung
2011-06
2011-03 AeroNDT 2010 Image processing
Optimization of Rod Anode Tubes for X-ray Inspection of Aircraft Engine Weldings
T. Fröba7, J. Steffen10
X-RAY WorX GmbH16, Garbsen, Germany
Radiographic Testing (RT), microfocus x-ray, aerospace, automotive, chemical and petrochemical, nuclear, offshore, power plant, heat exchanger, tank inspection, tubes and pipes, turbine, weld, crack, Digital Radiography

AeroNDT 2010
Session: Image processing
2011-03
Computed Tomography at BAM – From High Energy Technique to nm Scale
U. Ewert212
BAM Federal Institute for Materials Research and Testing1298, Berlin, Germany
Radiographic Testing (RT), computed tomography (CT), high energy radiography, laminography, microfocus x-ray, 3D Computed Tomography, micro-CT, microtomography
NDE-India 2009
2010-11
2010-08 ECNDT 2010 Computed Tomography
Study on Parameter Variation of an Industrial Computed Tomography Simulation Tool Concerning Dimensional Measurement Deviations
M. Reiter123, C. Heinzl137, D. Salaberger138, D. Weiß212, J. Kastner1115
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)161, Wels, Austria
2Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
Radiographic Testing (RT), computed tomography (CT), microfocus x-ray, 3D Computed Tomography, image quality, Simulation, Dimensional Measurement, metrology
ECNDT 2010
Session: Computed Tomography
2010-08
2010-08 ECNDT 2010 Computed Tomography
Uncertainty Visualization of Computed Tomography Datasets from Complex Components Using Statistical Analysis
M. Allerstorfer12, C. Heinzl137, J. Kastner1115, E. Gröller211
1Upper Austrian University of Applied Sciences (FH OÖ)161, Wels, Austria
2Institute of Computer Graphics and Algorithms; Vienna University of Technolog (TU)56, Vienna, Austria
Radiographic Testing (RT), microfocus x-ray, 3D Computed Tomography, statistical analysis, visualization
ECNDT 2010
Session: Computed Tomography
2010-08
2010-08 ECNDT 2010 Computed Tomography
Microfocus Computed X-Ray Tomography of Segregations in High Strength Aluminium Alloys
B. Harrer1,213, H. Degischer27, J. Kastner1,1115
1Upper Austrian University of Applied Sciences (FH OÖ)161, Wels, Austria
2Institute of Materials Science and Technology; Vienna University of Technolog (TU)56, Vienna, Austria
Radiographic Testing (RT), computed tomography (CT), microfocus x-ray, 3D Computed Tomography, micro-CT, microtomography, aerospace, automotive, Aluminium, materials characterization, defect characterization, microstructure, identification
ECNDT 2010
Session: Computed Tomography
2010-08
2010-08 ECNDT 2010 Computed Tomography
Porosity Determination in Firn Ice Cores Using Quantitative Computed Tomography Methods
M. Firsching19, V. Voland17, S. Burtzlaff6, N. Uhlmann29
Development Center X-ray technology (EZRT); Fraunhofer Institute for Integrated Circuits (IIS)177, Fürth, Germany
Radiographic Testing (RT), computed tomography (CT), microfocus x-ray, 3D Computed Tomography, micro-CT, Dual-energy, visualization, marine, porosity
ECNDT 2010
Session: Computed Tomography
2010-08
2010-08 ECNDT 2010 Computed Tomography
The Combined Use of Micro-CT Imaging, In-Situ Loading and Non-Rigid Image Registration for 3D Experimental Local Strain Mapping on Porous Bone Tissue Engineering Scaffolds under Compressive Loading
G. Kerckhofs16, G. Pyka15, D. Loeckx22, S. Van Bael12, J. Schrooten14, M. Wevers154
1aDepartment of Mechanical Engineering, Division of Production engineering, bDepartment of Metallurgy and Materials Engineering ; Catholic University of Leuven (KU Leuven) 101, Leuven, Belgium
2Medical imaging centre; University Ziekenhuis (U.Z. Leuven)2, Leuven, Belgium
Radiographic Testing (RT), microfocus x-ray, micro-CT, strain mapping, medical application, biomaterials, in-situ, strain, Deformation, mechanical properties
ECNDT 2010
Session: Computed Tomography
2010-08
2010-02 DGZfP 2009 Computertomographie
Genauigkeitsoptimierung der Röntgen-Computertomographie für die Geometriebestimmung und Visualisierung der Messunsicherheit
J. Kastner115, C. Heinzl37
R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)161, Wels, Austria
Radiographic Testing (RT), computed tomography (CT), microfocus x-ray, High-energy microfocus X-ray computed tomography (CT), Dual-energy, 3D imaging, 3D modeling, computer vision, tomography, visualization, aerospace, automotive

DE
DGZfP 2009
Session: Computertomographie
2010-02
2010-02 DGZfP 2009 Sonstiges
Dimensionelles Messen mit Helix-Computertomographie
T. Schön16, I. Bauscher8, T. Fuchs26, U. Hassler41, J. Hiller21, S. Kasperl38, S. Oeckl19, S. Schröpfer10, V. Weizel
aDevelopment Center X-ray technology (EZRT) bEntwicklungszentrum Röntgentechnik ; Fraunhofer Institute for Integrated Circuits (IIS)177, Fürth, Germany
NDT-wide, Radiographic Testing (RT), computed tomography (CT), microfocus x-ray, 3D Computed Tomography, micro-CT, microtomography, image quality, beam hardening, spatial resolution, 3D imaging, imaging, reconstruction, reconstruction algorithm, Aluminium, Quantitative NDT, metrology, quality control

DE
DGZfP 2009
Session: Sonstiges
2010-02
2009-12 AIPnD 2009 Radiografia - Radiografia digitale
Radiografia digitale con microfuoco in ingrandimento
G. Lombardi12, V. Jennarelli13, R. Bergamaschi2
1Precicast SA4, Novazzano, Switzerland
2Swisstest, Balerna, Switzerland
Radiographic Testing (RT), filmless radiography, microfocus x-ray, radiographic film, Digital Radiography, x-ray image quality, image quality, casting, Quantitative NDT, quality control, Italy
IT
AIPnD 2009
Session: Radiografia - Radiografia digitale
2009-12
2009-02 DGZfP 2008 Durchstrahlungsprüfung (RT)
Technische und wirtschaftliche Kriterien für die Bauartfestlegung von Strahlenschutzkabinen für die ZfP
U. Silberberg
Pontax, Lennestadt, Germany
Radiographic Testing (RT), computed tomography (CT), gamma radioscopy, high energy radiography, microfocus x-ray, radiation protection, 3D Computed Tomography, microtomography, Synchrotron Radiation, Computed Radiography, High-energy microfocus X-ray computed tomography (CT), scattered radiation
DE
DGZfP 2008
Session: Durchstrahlungsprüfung (RT)
2009-02
2009-02 DGZfP 2008 Simulation
Simulation eines industriellen 3D Röntgen Computertomographen zur verbesserten Geometriebestimmung
M. Reiter123, J. Kastner1115, S. Kunzmann2, H. Lettenbauer34, B. Chyba4, M. Mantler4
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)161, Wels, Austria
2Carl Zeiss Innovationszentrum für Messtechnik, Dresden, Germany
3Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
4Institut für Festkörperphysik; Vienna University of Technolog (TU)56, Vienna, Austria
Radiographic Testing (RT), computed tomography (CT), microfocus x-ray, 3D Computed Tomography, flat-panel detector, micro-CT, microtomography, x-ray imaging, scattered radiation, beam hardening, Modeling and Simulation, Simulation
DE
DGZfP 2008
Session: Simulation
2009-02
 
Page:
 -1-   2   3   4 
next pageNext
Actual Cooperations
Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window