where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)

Conference Proceedings, Articles, News, Exhibition, Forum, Network and more

where expertise comes together
- since 1996 -

Archive Authors Keywords


Publication Index



Select filters or/and search


Sort Pages
Check Filters!
Recenty New/Updated
NDT.net Journal
DGZfP Rail-2020
NDT Review
iCT 2020
PANNDT 2019
SINCE 2019
NDT Days 2019
AeroNDT 2019
more >
Recently New/UpdatedNDT.net JournalDGZfP Rail-2020NDT ReviewiCT 2020PANNDT 2019SINCE 2019NDT Days 2019AeroNDT 2019 more >

Keyword: metrology,
Search Results: 60
Title / Author(s) / Keywords PublicationDate
2020-02 iCT 2020 Image Processing and Deep Learning
Thu 15:40 Room 1
Surface Point Determination in Subvoxel Accuracy from Pre-Segmented Multi-Material Volume Data for Metrological Applications
L. Stopp, R. Christoph3, H. Weise3
Dresden University of Technology (TU Dresden)80, Dresden, Germany
segmentation, subvoxel accuracy, multi-material, industrial computed tomography, metrology

iCT 2020
Session: Image Processing and Deep Learning
Thu 15:40 Room 1
2020-02
2020-02 iCT 2020 Materials Characterisation
Wed 11:00 Room 1
Reference standards for XCT measurements of additively manufactured parts
A. Obaton14, C. Gottlieb Klingaa2, C. Rivet1, K. Mohaghegh32, S. Baier22, J. Lasson Andreasen42, L. Carli42, L. De Chiffre210
1Laboratoire National de Métrologie et d'Essais (LNE) 4, Paris, France
2aDepartment of Physics bDepartment of Mechanical Engineering; Technical University of Denmark (DTU)28, Kgs. Lyngby, Denmark
3Metrologic ApS2, Hørsholm, Denmark
4Novo Nordisk A/S, Hillerød5, Hillerød, Denmark
metrology, X-ray computed tomography (XCT), additive manufacturing, reference standards

iCT 2020
Session: Materials Characterisation
Wed 11:00 Room 1
2020-02
2020-02 iCT 2020 Metrology
Thu 09:00 Room 1
Influence of different mounting strategies on the random measurement error in industrial computed tomography
L. Schild3, M. Jung, B. Häfner3, G. Lanza13
wbk Institute of Production Science; Karlsruhe Institute of Technology (KIT)22, Eggenstein, Germany
mounting, measurement strategy, metrology, image quality

iCT 2020
Session: Metrology
Thu 09:00 Room 1
2020-02
2020-02 iCT 2020 Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
Investigation of the independence of the best assembly orientations with respect to X-ray source parameters in industrial computed tomography
N. Grozmani12, D. Chupina2, R. Schmitt117
1Laboratory for Machine Tools and Production Engineering WZL; RWTH Aachen University52, Aachen, Germany
2Bauman Moscow State Technical University (BMSTU)5, Moscow, Russia
Measurement Uncertainty, metrology, Computed Tomography, sinogram, workpiece orientation

iCT 2020
Session: Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
2020-02
2020-02 iCT 2020 Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
How much Influences Image Quality the Form Error in Industrial X-Ray CT?
D. Matern9, M. Töpperwien
YXLON International GmbH198, Hamburg, Germany
Metrology, Dimensional Measurement, X-Ray Computed Tomography, Traceability

iCT 2020
Session: Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
2020-02
2020-02 iCT 2020 Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
Phantom development applied to industrial tomography in composite material pipeline
W. Dias da Silva1, R. Lopes217, M. Viana Duarte3
1Petrobras Research Center36, Rio de Janeiro, Brazil
2Federal University of Rio de Janeiro (UFRJ)51, Rio de Janeiro, Brazil
3Federal University of Uberlândia (UFU)5, Uberlândia, Brazil
Metrology, Phantom, Quality Assurance, Composite

iCT 2020
Session: Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
2020-02
2019-06 NDE-India 2018 NDE Sensor, Systems, Software & Instrumentation
Computed Metro Tomography for faster Metrology and NDE
M. Arumugam, R. Varughese, G. Narayanan
Indian Space Research Organisation, Thiruvananthapuram, Kerala, India
Computed Tomography, Metrology, Defect analysis, Microfocus / Minifocus X-ray, Casting & 3D printing

NDE-India 2018
Session: NDE Sensor, Systems, Software & Instrumentation
2019-06
X-Ray and Computed Tomography as a Tool for Quality Assurance, Process Optimization and Metrology Inspections in the Field of Additive Manufacturing
P. Sperling3
YXLON International GmbH198, Hamburg, Germany
Radiographic testing (RT), Computed Tomography (CT), Metrology, Process Optimization, Additive Manufacturing (AM)

Defektoskopie 2018
2019-05
2019-03 iCT 2019 Metrology
Thu 09:00 Auditorium
CT geometry determination using individual radiographs of calibrated multi-sphere standards
B. Bircher5, F. Meli5, A. Küng5, R. Thalmann5
Laboratory for Length, Nano- and Microtechnology; Federal Institute of Metrology METAS5, Bern-Wabern, Switzerland
CT machine geometry, correction, multi-sphere standard, metrology

iCT 2019
Session: Metrology
Thu 09:00 Auditorium
2019-03
2019-03 iCT 2019 Metrology & Manufacturing
Thu 10:50 Auditorium
Uncertainty Evaluation of Pore Analysis for Additively Manufactured Parts using Cross Sections
L. Schild3, M. Fülling, B. Häfner3, G. Lanza13
wbk Institute of Production Science; Karlsruhe Institute of Technology (KIT)22, Eggenstein, Germany
Additive Manufacturing, Measurement Uncertainty, Metrology, Reference Object, Cross Section

iCT 2019
Session: Metrology & Manufacturing
Thu 10:50 Auditorium
2019-03
2019-03 iCT 2019 Metrology & Manufacturing
Thu 10:50 Auditorium
Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography
R. Schmitt17, A. Buratti3, N. Grozmani2
Laboratory for Machine Tools and Production Engineering WZL; RWTH Aachen University52, Aachen, Germany
computed tomography, workpiece placement, optimisation, metrology, measurement uncertainty

iCT 2019
Session: Metrology & Manufacturing
Thu 10:50 Auditorium
2019-03
2019-03 iCT 2019 New Methods & Optimization
Wed 13:50 Auditorium
Artifact reduction in X-ray computed tomography by multipositional data fusion using local image quality measures
G. Herl16, J. Hiller221, T. Sauer35
1Fraunhofer Anwendungszentrum CT in der Messtechnik4, Deggendorf, Germany
2Deggendorf Institute of Technology3, Deggendorf, Germany
3University of Passau5, Passau, Germany
X-ray computed tomography, data fusion, multipositional, multiorientational, local quality measures, metal artifact reduction, smART, unfiltered backprojection, metrology

iCT 2019
Session: New Methods & Optimization
Wed 13:50 Auditorium
2019-03
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
Error Investigations for a CT and Additive Manufacturing based Reverse Engineering Workflow
F. Bauer12, M. Schrapp28, J. Szijarto3
1Corporate Technology; Siemens AG, Corporate Technology (CT)65, Munich, Germany
2Siemens Healthineers, Munich, Germany
3Siemens Power Generation Services,, Finspang, Sweden
turbine blade, metrology, micro-CT, Computed Tomography, Non-destructive testing, additive manufacturing, Reverse Engineering, Multimodal CT, Optical Scanning

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
Validation of a Method for the Optimization of Scan Parameters for Measuring with Computed Tomogography
R. Christoph13, C. Leinweber24, A. Fischer2, H. Weise13, M. Kachelrieß39
1Institute of Manufacturing Science and Engineering; Dresden University of Technology (TU Dresden)80, Dresden, Germany
2Werth Messtechnik GmbH6, Giessen, Germany
3Division of X-Ray Imaging and CT; German Center for Cancer Research (DKFZ)9, Heidelberg, Germany
automation, scan parameters, cone-beam CT, industrial computed tomography, metrology

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
CT machine geometry changes under thermal load
B. Bircher5, F. Meli5, A. Küng5, R. Thalmann5
Laboratory for Length, Nano- and Microtechnology; Federal Institute of Metrology METAS5, Bern-Wabern, Switzerland
CT machine geometry, thermal influences, geometry measurement system, metrology

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
Investigation of positioning accuracy of industrial robots for robotic-based X-ray computed tomography
P. Landstorfer1, J. Hiller221, M. Herbst2
1Fraunhofer Anwendungszentrum CT in der Messtechnik4, Deggendorf, Germany
2Deggendorf Institute of Technology3, Deggendorf, Germany
Robots, Metrology, Arbitrary Geometry

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-03 iCT 2019 Short talks
Thu 13:50 Auditorium
Analysis of Cone Beam Artefact Influences with Respect to Calibration of Metrology Qualified X-Ray Computed Tomogrophy Systems
D. Matern9
YXLON International GmbH198, Hamburg, Germany
Computed Tomography, Metrology, Artefacts, Calibration, Simulation

iCT 2019
Session: Short talks
Thu 13:50 Auditorium
2019-03
2019-03 iCT 2019 Short talks
Thu 13:50 Auditorium
Custom-made software tool for the automatic implementation of surface extraction methods based on gradient operators
R. Jiménez-pacheco1, S. Ontiveros-Zepeda2, J. Yagüe-Fabra33
1Centro Universitario de la Defensa (CUD)3, Zaragoza, Spain
2Universidad Autónoma de Baja California, Tecate, Mexico
3University of Zaragoza18, Zaragoza, Spain
Edge detection, metrology, computed tomography, software

iCT 2019
Session: Short talks
Thu 13:50 Auditorium
2019-03
2019-03 iCT 2019 Short talks
Thu 13:50 Auditorium
On nominal-actual comparisons for additive manufacturing applications
Léonard, Fabien; Bruno, Giovanni
AM, computed tomography, X-ray CT, metrology, data processing, data evaluation

iCT 2019
Session: Short talks
Thu 13:50 Auditorium
2019-03
2019-03 AeroNDT 2018 NDT and Additive Manufacturing
Utilising Advanced Computed Tomography as NDT Technique in Additive Manufacturing
J. Lübbehüsen7, G. Zacher2
Phoenix X-ray; GE Inspection Technologies69, Wunstorf, Germany
Additive Manufacturing, AM, Computed Tomography, CT, 3D Visualization, Metrology, Standardisation ISO/ASTM

AeroNDT 2018
Session: NDT and Additive Manufacturing
2019-03
 
Page:
 -1-   2   3 
next pageNext
Actual Cooperations
Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window