where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)

Conference Proceedings, Articles, News, Exhibition, Forum, Network and more

where expertise comes together
- since 1996 -

Archive Authors Keywords


Publication Index



Select filters or/and search


Sort Pages
Check Filters!
Recenty New/Updated
NDT.net Journal
DGZfP Rail-2020
NDT Review
iCT 2020
PANNDT 2019
SINCE 2019
NDT Days 2019
AeroNDT 2019
more >
Recently New/UpdatedNDT.net JournalDGZfP Rail-2020NDT ReviewiCT 2020PANNDT 2019SINCE 2019NDT Days 2019AeroNDT 2019 more >

Keyword: X-ray computed tomography,
Search Results: 61
Filter Results ...
Publications
iCT 2019 (12)
iCT 2018 (7)
iCT 2012 (6)
iCT 2016 (6)
iCT 2014 (4)
iCT 2020 (4)
DIR 2015 (4)
iCT 2017 (3)
WCNDT 2016 (3)
WCNDT 2012 (2)
AeroNDT 2014 (2)
DGZfP 2017 (1)
DGZfP RT-2017 (1)
NDE-India 2017 (1)
NDT-Slovenia 2017 (1)
NDT Review (1)
DIR 2019 (1)
ECNDT 2014 (1)
NDE-India 2014 (1)

Languages
English (59)
German (2)

Exhibitors (1)
YXLON Internat.. 1
Title / Author(s) / Keywords PublicationDate
2020-02 iCT 2020 Metrology
Thu 10:50 Room 1
Uncertainty of CT dimensional measurements performed on metal additively manufactured lattice structures
F. Zanini15, M. Sorgato2, E. Savio22, S. Carmignato118
1University of Padova (UNIPD), Vicenza, Italy
2University of Padova (UNIPD)33, Padova, Italy
X-ray computed tomography, additive manufacturing, cellular structures, dimensional metrology, accuracy

iCT 2020
Session: Metrology
Thu 10:50 Room 1
2020-02
2020-02 iCT 2020 Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
How much Influences Image Quality the Form Error in Industrial X-Ray CT?
D. Matern9, M. Töpperwien
YXLON International GmbH198, Hamburg, Germany
Metrology, Dimensional Measurement, X-Ray Computed Tomography, Traceability

iCT 2020
Session: Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
2020-02
2020-02 iCT 2020 Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
Investigation of the eye formation in semi-hard cheese by using X-ray Computed Tomography
J. Auer1, M. Reiter129, S. Senck124, A. Reiter2, J. Herr12, J. Kastner1124, K. Mathmann14
1Upper Austrian University of Applied Sciences (FH OÖ)172, Wels, Austria
2Berglandmilch eGen, Aschbach-Markt, Austria
X-ray Computed Tomography, eye formation, Iterative Artifact Reduction, beam hardening

iCT 2020
Session: Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
2020-02
2020-02 iCT 2020 Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
3D spatial resolution evaluation for helical CT according to ASTM E1695 – 95
J. Lázňovský13, A. Břínek13, T. Zikmund19, B. Young2, Z. Patáková2, J. Kaiser19
1Central European Institute of Technology; Brno University of Technology (BUT)227, Brno, Czech Republic
2Thermo Fisher Scientific2, Brno, Czech Republic
spatial resolution, helical CT, X-ray computed tomography, modulation transfer function

iCT 2020
Session: Poster Exhibition, Dinner and Lab-Tours
Wed 17:25 Room 1
2020-02
2019-11 DIR 2019 CT & Multi-angle Radiography
High definition X-ray Source based on Carbon Nanotube Emitter for Micro CT application
X. LI1, M. LIU1, J. ZHOU1, X. WU1, Q. WU2, L. Ren2, J. ZHENG2, Z. CHEN2
1University of Electronic Science and Technology of China12, Chengdu, China
2Guangzhou Haozhi Imaging Technology2, Guangzhou, China
Radiographic Testing (RT), microfocus x-ray, micro-CT, carbon nanotubes, X-ray computed tomography, Microfocus X-ray Source

DIR 2019
Session: CT & Multi-angle Radiography
2019-11
2019-07 NDT Review Journal of Nondestructive Evaluation (Springer)
Introduction of a Surface Characterization Parameter Sdr prime for Analysis of Re-entrant Features
A. Townsend3, L. Pagani2, P. Scott3, L. Blunt4
EPSRC Future Metrology Hub, School of Computing and Engineering; University of Huddersfield12, Huddersfield, United Kingdom
X-ray computed tomography, Additive manufacturing, ISO 25178, Surface texture, Re-entrant surfaces

NDT Review
Session: Journal of Nondestructive Evaluation (Springer)
2019-07
2019-03 iCT 2019 Algorithms & Reconstruction
Wed 16:20 Auditorium
An Interactive Visual Comparison Tool for 3D Volume Datasets represented by Nonlinearly Scaled 1D Line Plots through Space-filling Curves
J. Weissenböck111, B. Fröhler16, E. Gröller211, J. Sanctorum33, J. De Beenhouwer317, J. Sijbers320, S. Ayalur Karunakaran42, H. Hoeller42, J. Kastner1124, C. Heinzl138
1Research Group Computed Tomography; Upper Austrian University of Applied Sciences (FH OÖ)172, Wels, Austria
2Institute of Computer Graphics and Algorithms; Vienna University of Technolog (TU)57, Vienna, Austria
3aInstitute of Computer Graphics and Algorithms bimec-VisionLab, Department of Physics; University of Antwerpen36, Antwerpen, Belgium
4Fischer Advanced Composite Components (FACC)15, Ried, Austria
Radiographic Testing (RT), Other Methods, X-ray computed tomography, visual analysis, comparative visualization, Hilbert curve, nonlinear scaling

iCT 2019
Session: Algorithms & Reconstruction
Wed 16:20 Auditorium
2019-03
2019-03 iCT 2019 Metrology
Thu 09:00 Auditorium
Uncertainty for uncorrected measurement results in X-ray computed tomography
H. Villarraga-Gómez1, S. Smith22
1Nikon Metrology, Inc.11, Brighton, MI, USA
2University of North Carolina3, Charlotte, NC, USA
NDT-wide, Measurement Uncertainty, microtomography, Dimensional metrology, Cone beam computed tomography, nondestructive evaluation, nondestructive testing, X-ray computed tomography, CMM, Industrial computed tomography, non-destructive inspection, bias, RSSU, SUMU, MPE (maximum permissible error), Nikon Metrology

iCT 2019
Session: Metrology
Thu 09:00 Auditorium
2019-03
2019-03 iCT 2019 Metrology & Manufacturing
Thu 10:50 Auditorium
Experimental investigation on the accuracy of XCT measurement of fiber length in fiber reinforced polymers
F. Zanini15, G. Gerardi1, J. Weissenböck211, C. Heinzl238, J. Kastner2124, S. Carmignato118
1University of Padova (UNIPD)33, Padova, Italy
2Research Group Computed Tomography; Upper Austrian University of Applied Sciences (FH OÖ)172, Wels, Austria
X-ray computed tomography, fiber length measurement, fiber reinforced polymers, accuracy evaluation

iCT 2019
Session: Metrology & Manufacturing
Thu 10:50 Auditorium
2019-03
2019-03 iCT 2019 New Methods & Optimization
Wed 13:50 Auditorium
Artifact reduction in X-ray computed tomography by multipositional data fusion using local image quality measures
G. Herl16, J. Hiller221, T. Sauer35
1Fraunhofer Anwendungszentrum CT in der Messtechnik4, Deggendorf, Germany
2Deggendorf Institute of Technology3, Deggendorf, Germany
3University of Passau5, Passau, Germany
X-ray computed tomography, data fusion, multipositional, multiorientational, local quality measures, metal artifact reduction, smART, unfiltered backprojection, metrology

iCT 2019
Session: New Methods & Optimization
Wed 13:50 Auditorium
2019-03
2019-03 iCT 2019 New Methods & Optimization
Wed 13:50 Auditorium
Helical XCT measurement for correlative imaging
A. Břínek3, J. Lázňovský3, T. Zikmund9, J. Salplachta3, J. Kaiser9
Central European Institute of Technology; Brno University of Technology (BUT)227, Brno, Czech Republic
X-ray computed tomography, Laser-induced breakdown spectroscopy, Correlative imaging

iCT 2019
Session: New Methods & Optimization
Wed 13:50 Auditorium
2019-03
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
Characterization of the effects of detector angular misalignments and accuracy enhancement of X-ray CT dimensional measurements
V. Aloisi15, J. Schlecht14, E. Ferley14, S. Carmignato218
1North Star Imaging, Inc. (NSI)11, Rogers, MN, USA
2Department of Management and Engineering; University of Padova (UNIPD)33, Padova, Italy
X-ray Computed Tomography, Dimensional metrology, Traceability, Accuracy, Geometrical errors, Errorscorrection

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
CCD and scientific-CMOS detectors for submicron laboratory based X-ray Computed tomography
J. Salplachta13, T. Zikmund19, M. Horváth22, Y. Takeda32, K. Omote32, L. Pina24, J. Kaiser19
1Central European Institute of Technology; Brno University of Technology (BUT)227, Brno, Czech Republic
2Rigaku Innovative Technologies Europe, s.r.o.,, Praha, Czech Republic
3Rigaku Corporation2, Tokyo, Japan
X-ray imaging, X-ray Computed Tomography, image detectors, CCD, sCMOS, image quality evaluation

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
Evaluation of the sinogram-based iterative reconstruction algorithm in region-of-interest tomography
Trinca, Dragos; Libin, Eduard
iterative algorithm, region-of-interest (ROI) tomography, X-ray computed tomography

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-03 iCT 2019 Poster exhibition
Thu 16:00 Agora
Development of Reference Samples to Study the Effects of Systematic Errors of Industrial X-ray Computed Tomography
W. SUN2, S. Brown3
National Physical Laboratory (NPL)19, Teddington, United Kingdom
X-ray computed tomography, reference sample, systematic errors

iCT 2019
Session: Poster exhibition
Thu 16:00 Agora
2019-03
2019-03 iCT 2019 Short talks
Thu 13:50 Auditorium
Comparison of different voxel size calibration strategies
M. Katic2, G. Barsic2
Faculty of Mechanical Engineering & Naval Architecture; University of Zagreb52, Zagreb, Croatia
X-ray computed tomography, Coordinate measuring machines, voxel size

iCT 2019
Session: Short talks
Thu 13:50 Auditorium
2019-03
2019-03 iCT 2019 Short talks
Thu 13:50 Auditorium
An experimental study on segmentation in X-Ray Computed Tomography
G. Moroni, S. Petrò
Department of Mechanical Engineering; Politecnico di Milano84, Milano, Italy
X-Ray computed Tomography, Uncertainty, Segmentation

iCT 2019
Session: Short talks
Thu 13:50 Auditorium
2019-03
2019-03 iCT 2019 Short talks
Thu 13:50 Auditorium
Simulation-based sensitivity analysis of geometrical misalignments in X-ray computed tomography systems for dimensional metrology – detector angular misalignments
E. Sbettega, F. Zanini5, S. Carmignato18
Department of Management and Engineering; University of Padova (UNIPD)33, Padova, Italy
X-ray computed tomography, dimensional metrology, geometrical errors, sensitivity analysis

iCT 2019
Session: Short talks
Thu 13:50 Auditorium
2019-03
2018-06 NDT-Slovenia 2017 Composites
Crack Profile Reconstruction of CFRP-CFRP Bonded Joints From Optical Backscatter Reflectometry and Comparison with X-Ray Computed Tomography
A. Gianneo10, M. Carboni33, A. Bernasconi2
Department of Mechanical Engineering; Politecnico di Milano84, Milano, Italy
Radiographic Testing (RT), non destructive testing, X-ray computed tomography, optical backscatter reflectometry, Single Lap Joints, Carbon Fiber Reinforced Composites

NDT-Slovenia 2017
Session: Composites
2018-06
NDT Methods to determine the integrity of ultrasonic welds for Lithium
H. Ravichandran12, D. Sethy12, V. Rikka22, K. Balasubramaniam1114, R. Prakash22, R. Gopalan22, G. Sundararajan2
1aDepartment of Mechanical Engineering bDepartment of Mechanical Engineering & CNDE; Indian Institute of Technology Madras (IITM)135, Chennai, India
2Centre for Automotive Energy Materials(CAEM); International Advanced Research Centre for Powder Metallurgy & New Materials (ARCI) 5, Hyderabad, India
Ultrasonic Welding, Thermography, X-Ray Computed Tomography, Lithium ion Battery Tabs, Additive Manufacturing, Fatigue Testing

NDE-India 2017
2018-04
 
Page:
 -1-   2   3   4 
next pageNext
Actual Cooperations
Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window