where expertise comes together - since 1996

Web's Largest Portal of Nondestructive Testing (NDT)
Open Access Database (Conference Proceedings, Articles, News), Exhibition, Forum, Network

Database Search Authors & Institutions Keywords




Search in fields and body (full-text)


sorted by results/page
[Reset]
Check old settings before new Search
 Recently New  
NDT.net Issue 2018-12
  • NDT.net Journal

  • NDT.net Review

  • SHM-NDT 2018

NDT.net Issue 2018-11
  • EWSHM 2018

NDT.net Issue 2018-10
  • ZfP-Zeitung

  • NDT Canada 2018

NDT.net Issue 2018-09
  • DGZfP 2018

NDT.net Issue 2018-08
  • ECNDT 2018

8th Conference on Industrial Computed Tomography (iCT) 2018, 6-9 Feb, Wels, Austria


iCT 2018 Keywords Authors & Institutions

More Publications: •iCT 2017iCT 2016iCT 2014iCT 2012iCT 2008iCT 2010
Forthcoming Publications: - 9th International Conference on Industrial Computed Tomography (iCT 2019)
Search Results: 69 in Date '2018-02-01'
Exhibitors' Results (6)
Nikon Metrolog.. 2
TESTIA GmbH.. 2
Volume Graphic.. 1
YXLON Internat.. 1
Title / Author(s) / Keywords Session
Preface of the 8th Conference on Industrial Computed Tomography (iCT) 2018
J. Kastner106
Research Group Computed Tomography; Upper Austrian University of Applied Sciences (FH OÖ)149, Wels [Austria]
Radiographic Testing (RT), computed tomography
 
Preface
Fully Convolutional Deep Network Architectures for Automatic Short Glass Fiber Semantic Segmentation from CT scans
T. Konopczyński12, D. Rathore2, J. Rathore35, T. Kröger12, L. Zheng22, C. Garbe23, S. Carmignato314, J. Hesser22
1Department of Mathematics and Informatics; Volume Graphics GmbH34, Heidelberg [Germany]
2aDepartment of Radiation Oncology bInterdisciplinary Center for Scientific Computing (IWR); Universität Heidelberg4, Heidelberg [Germany]
3aDepartment of Management and Engineering bDepartment of Management and Engineering (DTG); University of Padova (UNIPD)27, Padova [Italy]
segmentation, deep learning, x-ray CT, short glass fibers

 
Algorithms, image processing and visualisation
A new calibration-free beam hardening reduction method for industrial CT
T. Würfl1, N. Maass22, F. Dennerlein2, A. Maier13
1Pattern Recognition Lab; University of Erlangen-Nürnberg (FAU)35, Erlangen [Germany]
2Siemens AG2, Erlangen [Germany]

 
Algorithms, image processing and visualisation
Detection of Narrow Gaps Using Hessian Eigenvalues for Shape Segmentation on CT Volume of Assembled Parts
S. Watanabe, Y. Ohtake13, Y. Nagai10, H. Suzuki13
School of Engineering; University of Tokyo57, Tokyo [Japan]
CT volume segmentation, Gap detection, Shape extraction of assembled parts

 
Algorithms, image processing and visualisation
Evaluation of internal defects in additive manufactured metallic network structures by Computed Tomography
L. Pejryd5
Scool of Science and Technology; Örebro University5, Örebro [Sweden]
Selective laser melting, aluminium, titanium, computed tomography

 
Materials Characterisation
Synchrotron based absorption edge tomography for 3D characterization of the microstructure of Mg-Y-Zn alloys
C. Gollwitzer18, S. Cabeza16, G. Garces23
1BAM Federal Institute for Materials Research and Testing1256, Berlin [Germany]
2Department of Physical Metallurgy; National Center for Metallurgical Research (CENIM-CSIC)3, Madrid [Spain]
Other Methods, Synchrotron CT, Absorption edge tomography, differential tomography, LPSO

 
Materials Characterisation
Computed Tomography Inspection of Additive Manufactured Components in Aeronautic Industry
D. Kiefel18, M. Scius-Bertrand1, R. Stoessel223
1TESTIA GmbH2, Munich [Germany]
2Airbus Group Innovations8, Munich [Germany]
Computed Tomography, 3D-Printing, Additive Manufacturing, CT-Inspection, Aeronautic, Aerospace

 
Materials Characterisation
Evaluation of Fluid Transport Characteristics in Natural Stones Using Dual Source X-Ray Radiography
P. Koudelka2, V. Koudelkova, T. Doktor2, I. Kumpova12, T. Fila5, P. Zlamal2, D. Kytýr3, D. Vavrik17
Institute of Theoretical and Applied Mechanics ASCR; Academy of Sciences of the Czech Republic (ASCR/CAS)103, Prague [Czech Republic]
Dual Source X-Ray Radiography, Fluid Transport, Weathering effects, Maastricht calcarenite

 
Materials Characterisation
3D CT as Quality Control Tool in Advanced Composite Manufacturing
J. Ecker1, C. Fürst13, C. Unterweger1, B. Plank242, A. Haider1
1Kompetenzzentrum Holz GmbH3, Linz [Austria]
2School of Engineering and Environmental Sciences; Upper Austrian University of Applied Sciences (FH OÖ)149, Wels [Austria]
3D printing, computed tomography, porous carbon, wood polymer composite, SiC ceramic

 
Materials Characterisation
Determination of pore size distribution in Tannin- and Lignin-based foams using X-ray microcomputed tomography
J. Glinz13, S. Senck116, J. Kastner1106, G. Tondi2
1Research Group Computed Tomography; Upper Austrian University of Applied Sciences (FH OÖ)149, Wels [Austria]
2University of Applied Science Salzburg6, Salzburg [Austria]
Radiographic Testing (RT), computed tomography, X-ray microcomputed tomography, 3D characterization

 
Materials Characterisation
A geometry measurement system for a dimensional cone beam CT
B. Bircher2, F. Meli2, A. Küng2, R. Thalmann2
Federal Institute of Metrology METAS2, Bern-Wabern [Switzerland]
Computed tomography (CT), dimensional metrology, 9 DoF CT geometry

 
Metrology
Examination of a Method for the Optimization of Scan Parameters for Measuring with Computed Tomography
R. Christoph1, H. Weise1, C. Leinweber23, M. Kachelrieß26
1Institute of Manufacturing Science and Engineering; Dresden University of Technology (TU Dresden)69, Dresden [Germany]
2German Center for Cancer Research (DKFZ)6, Heidelberg [Germany]
automation, scan parameters, cone-beam CT, industrial computed tomography, metrology

 
Metrology
Voxel dataset noise reduction algorithm based on CMM reference measurements for geometrical tolerance analysis of prismatic test pieces
C. Baldo16, T. Fernandes25, G. Donatelli210, K. Doytchinov3, K. Vrantzaliev3
1Center for Engineering, Modeling and Applied Social Sciences (CECS); Federal University of ABC (UFABC)6, Santo André [Brazil]
2aReference Centres in Innovative Technologies bReference Centers in Innovative Technologies; CERTI Foundation11, Florianópolis [Brazil]
3Quality Vision International - QVI; KOTEM Hungary Ltd, Budapest [Hungary]
industrial tomography, measurement uncertainty, point cloud generation, geometrical tolerance verification

 
Metrology
Form estimation for X-ray computed tomography measurement
L. Pagani, S. Lou2, W. Zeng2, X. Jiang2, P. Scott2
aEPSRC bEPSRC Centre for Innovative Manufacturing in Advanced Metrology; University of Huddersfield9, Huddersfield [United Kingdom]
X-ray computed tomography, triangular mesh, surface characterisation, form estimation

 
Metrology
Verifying the measurement accuracy for multiple-scan X-ray cone-beam CT measurements
D. Weiß11, W. Kimmig, R. Lonardoni2, C. Kuhn12
Carl Zeiss Industrielle Messtechnik GmbH20, Oberkochen [Germany]
X-ray cone beam CT, measurement accuracy, multi-scan, calibration artifact, ball rails
 
Metrology
Determining spectrum-dependent source and detector positions in cone-beam CT
J. Illemann16, U. Neuschaefer-Rube112, M. Bartscher131, D. Bate2
1Working group 5.34: Multi-sensor coordinate metrology; Physikalisch-Technische Bundesanstalt (PTB)40, Braunschweig [Germany]
2Nikon Metrology UK Ltd5, Tring [United Kingdom]
magnification, source position, detector position, traceability, x-ray spectrum dependence

 
Metrology
On Gauge Orientation for the Qualification of Industrial Computed Tomography
D. Matern5, F. Herold28
YXLON International GmbH180, Hamburg [Germany]
Metrology, Computed Tomography, Dimensional Measurement, Reference Standard

 
Metrology and Dual-Energy Imaging
Influence of surface roughness on measurement uncertainty in Computed Tomography
L. Schild, A. Kraemer3, D. Reiling, H. Wu, G. Lanza11
wbk Institute of Production Science; Karlsruhe Institute of Technology (KIT)20, Eggenstein [Germany]
Other Methods, Measurement Uncertainty, Dimensional metrology, surface quality, additive manufacturing, reference measurement

 
Metrology and Dual-Energy Imaging
Simulation-based correction of systematic errors for CT measurements
A. Müller4, F. Wohlgemuth, T. Hausotte5
Institute of Manufacturing Metrology; University of Erlangen-Nürnberg (FAU)35, Erlangen [Germany]
X-ray computed tomography, simulation, artefacts, correction, systematic error

 
Metrology and Dual-Energy Imaging
Reading closed historical manuscripts using dual-source dual-energy X-Ray tomography
I. Kumpova12, D. Vavrik17, M. Vopalensky6
Institute of Theoretical and Applied Mechanics ASCR; Academy of Sciences of the Czech Republic (ASCR/CAS)103, Prague [Czech Republic]
X-Ray tomography, Dual-source CT, Dual-energy CT, Iron gall ink, Historical manuscript

 
Metrology and Dual-Energy Imaging
 
Page:
 -1-   2   3   4 
next pageNext
Forthcoming Open Access Contributors

2018 Dec 19-21

2019 Feb 13-15

2019 Jun 17-21

2019 Jun 18-20

SINCE 2019
2019 Dec 4-5

© NDT.net - The Web's Largest Portal of Nondestructive Testing (NDT) ISSN 1435-4934

Open Access Database, |Conference Proceedings| |Articles| |News| |Exhibition| |Forum| |Professional Network|