where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)

Conference Proceedings, Articles, News, Exhibition, Forum, Network and more

where expertise comes together
- since 1996 -
Issue '2012-12'
Vol.17 No.12 - The e-Journal of Nondestructive Testing - ISSN 1435-4934
Summary

In this December issue we present the proceedings of the International Conference on Industrial Computed Tomography (ICT), 19-21 September 2012, Wels, Austria. The next iCT 2014 will be held in 2014
...
, Feb 25-28, Wels, Austria.

The winner of this evaluation period of our permanent photo campaign is Henry Peter Brunskill from Sheffield United Kingdom. Thanks to Olympus NDT, our sponsor of this campaign, the winner received an Olympus digital camera. Although we interrupt the presentation of prize for the best photo, the "I Like" ranking is still continuing in MyNDT >> here.

46 Articles:4th Conference on Industrial Computed Tomography (iCT), 19-21 September 2012, Wels, Austria
Copyright Shaker Verlag 2012 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior
...
permission of the publishers. Printed in the Netherlands. ISBN 978-3-8440-1281-1 ISSN 1610-4773 Shaker Verlag GmbH • P.O. BOX 101818 • D-52018 Aachen Phone: 0049/2407/9596-0 • Telefax: 0049/2407/9596-9 Internet: www.shaker.de • e-mail: info@shaker.de
>
New Events & Web Resources |more|
13 News in this issue
New Bracelet scanner is suitable for TOFD and Phased Array
Phoenix Inspection Systems Ltd
Olympus NDT Introduces New TOFD Capabilities for the OmniScan MX2 Flaw Detector
Olympus Scientific Solutions Americas (OSSA)
FirstMap™ from Imperium - the Corrosion Mapping application the Oil and Gas Industry has been waiting for
Imperium Inc
Introducing WiFi on PosiTector Advanced
DeFelsko Corporation
TOFD Calculation Tool for iPad/iPhone App
Tango2020
New release version of Y.FGUI 3.5 offers even more options
YXLON International GmbH
TWI publishes ground breaking developments for friction stir welding of steel
TWI Ltd (The Welding Institute)
CIVA Newsletter November 2012
EXTENDE
UniWest Brings the Only 4-Frequency Eddy Current Portable Instrument with Integration Ability to the Marketplace (US-454A)
UniWest
Featured Products: Train axle Scanner
TecScan Systems
TÜV Rheinland Opens New NDE Services Operation in Richland, Miss.
TÜV Rheinland Industrial Solutions
Governmental Safety Regulations Globally Increase Demand for Nondestructive Test Equipment, Finds Frost & Sullivan
Frost & Sullivan
Analysis of the Global Nondestructive Test Equipment Market - Understanding Industry Dynamics Key to Growth
Frost & Sullivan
Table of Contents
60 Articles in
Issue: 2012-12
Title / Author(s) / Keywords Publication
open document New Bracelet scanner is suitable for TOFD and Phased Array
Phoenix Inspection Systems Ltd67, Warrington, United Kingdom
NEWS
NDT.net Journal
open document Olympus NDT Introduces New TOFD Capabilities for the OmniScan MX2 Flaw Detector
Olympus Scientific Solutions Americas (OSSA)226, Waltham, MA, USA
NEWS
NDT.net Journal
open document FirstMap™ from Imperium - the Corrosion Mapping application the Oil and Gas Industry has been waiting for
Imperium Inc18, Beltsville, MD, USA
NEWS
NDT.net Journal
open document Introducing WiFi on PosiTector Advanced
DeFelsko Corporation2, Ogdensburg, NY, USA
NEWS
NDT.net Journal
open document TOFD Calculation Tool for iPad/iPhone App
Tango2020, Edmonton, Canada
NEWS 1 /1
NDT.net Journal
open document New release version of Y.FGUI 3.5 offers even more options
YXLON International GmbH194, Hamburg, Germany
NEWS
NDT.net Journal
open document TWI publishes ground breaking developments for friction stir welding of steel
TWI Ltd (The Welding Institute)183, Great Abington, Cambridge, United Kingdom
NEWS
NDT.net Journal
open document CIVA Newsletter November 2012
EXTENDE98, Massy, France
NEWS
NDT.net Journal
open document UniWest Brings the Only 4-Frequency Eddy Current Portable Instrument with Integration Ability to the Marketplace (US-454A)
UniWest4, Pasco, WA, USA
NEWS
NDT.net Journal
open document Featured Products: Train axle Scanner
TecScan Systems24, Boucherville, Quebec, Canada
NEWS
NDT.net Journal
open document TÜV Rheinland Opens New NDE Services Operation in Richland, Miss.
TÜV Rheinland Industrial Solutions10, Boxborough, MA, USA
NEWS
NDT.net Journal
open document Governmental Safety Regulations Globally Increase Demand for Nondestructive Test Equipment, Finds Frost & Sullivan
Frost & Sullivan23, London, United Kingdom
NEWS
NDT.net Journal
open document Analysis of the Global Nondestructive Test Equipment Market - Understanding Industry Dynamics Key to Growth
Frost & Sullivan23, London, United Kingdom
NEWS
NDT.net Journal
Wall Thickness Measurement
L. Pick3, R. Pincu11, R. Lieberman2
Vidisco Ltd.16, Or-Yehuda, Israel
Radiographic Testing (RT), wall thickness measurement, Pipeline Inspection, pitting, pipe wall thickness measurement and pitting

NDT.net Journal
iCT 2012 Non-destructive Testing and 3D Materials Characterisation - Visualisation and Simulation
μCT on narrowly fractured natural rock samples from a hydrocarbon reservoir
M. Voorn1, A. Rath1,22, U. Exner1,32
1Department of Geodynamics and Sedimentology; Vienna University of Technolog (TU)56, Vienna, Austria
2OMV ES-G Production Geology & Geophysics, Vienna, Austria
3Natural History Museum2, Vienna, Austria
μCT, geology, reservoir, fracture, porosity, permeability, segmentation, multiscale Hessian

iCT 2012
Session: Non-destructive Testing and 3D Materials Characterisation - ...
iCT 2012 Dimensional Measurement - Measurement Parameters
Determination of Optimal CT Scan Parameters Using Radial Basis Function Neural Networks
R. Giedl-Wagner12, T. Miller14, B. Sick2
1Deggendorf University of Applied Sciences3, Deggendorf, Germany
2Intelligent Embedded Systems Lab; University of Kassel87, Kassel, Germany
Other Methods, Artificial Neural Network, X-ray computed tomography, Radial Basis Function Network

iCT 2012
Session: Dimensional Measurement - Measurement Parameters
iCT 2012 Dimensional Measurement - Keynote
CT for Industrial Metrology - Accuracy and Structural Resolution of CT Dimensional Measurements
S. Carmignato17, A. Pierobon2, P. Rampazzo, M. Parisatto, E. Savio
aDepartment of Management and Engineering bDepartment of Industrial Engineering cDepartment of Geosciences; University of Padova (UNIPD)32, Padova, Italy
Radiographic Testing (RT), Resolution, Dimensional metrology, Computed Tomography, measurement accuracy, CT, metrological verification, structural resolution

iCT 2012
Session: Dimensional Measurement - Keynote
iCT 2012 Dimensional Measurement - Measurement Parameters
Investigation on the influence of image quality in X-ray CT metrology 229
P. Müller1, J. Hiller121, A. Cantatore1, M. Bartscher233, L. De Chiffre18
1Department of Mechanical Engineering; Technical University of Denmark (DTU)25, Kgs. Lyngby, Denmark
2Physikalisch-Technische Bundesanstalt (PTB)43, Braunschweig, Germany
Other Methods, image quality, Computed Tomography, spatial resolution, pixel noise, dimensional CT measurement

iCT 2012
Session: Dimensional Measurement - Measurement Parameters
iCT 2012 Dimensional Measurement - Measurement Parameters
Assessing the Effect of Focal Spot Movement on the Accuracy of CT Results by using a Simulation Technique
T. Fröba7, J. Steffen10
X-RAY WorX GmbH16, Garbsen, Germany
Dimensional Measurement, Microfocus X-ray Source, X-ray Source Stability, High Resolution Computed Tomography

iCT 2012
Session: Dimensional Measurement - Measurement Parameters
iCT 2012 Dimensional Measurement - Measurement Parameters
Evaluation of transmission based image quality optimisation for X-ray computed
M. Reiter123, S. Kasperl238, C. Kuhn313, M. Erler34, D. Weiß312, C. Heinzl137, C. Gusenbauer131, J. Kastner1115
1R&D Competence Center; Upper Austrian University of Applied Sciences (FH OÖ)161, Wels, Austria
2Development Center X-ray technology (EZRT); Fraunhofer Institute for Integrated Circuits (IIS)177, Fürth, Germany
3 ; Carl Zeiss Industrielle Messtechnik GmbH21, Oberkochen, Germany
Radiographic Testing (RT), parameter optimisation, X-ray computed tomography, transmission, optimised scan, EN 16016

iCT 2012
Session: Dimensional Measurement - Measurement Parameters
 
Page:
 -1-   2   3 
next pageNext
Actual Cooperations
Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window