A Major Leap Forward in IRIS UT

Eddyfi56, Quebec, Canada

Eddyfi's internal rotary inspection UT solution (IRIS) is the most powerful system of its kind on the market. It can display all views in real time - A-scan, B-scan, and C-scan - a unique feature in the industry. It also boasts of three independent gate settings and it handles walls that can be as much as 50% thinner than those of its closest competitor (patent pending). The system also virtually has no dead zones, thanks to an improved centering system and better data processing, which prevents loss of data.

The Eddyfi IRIS solution is also two to three times faster than its closest competitor with turbines revolving at 100 RPS and an acquisition rate of 25 kHz, making it possible to pull the probe much faster during inspections. To top it off, the system allows you to analyze data on the fly and produce reports during the inspection. What does this mean for you? More tubes inspected in less time, no more bad calls from ghost echoes, shorter overall inspection times, and above all else, shorter down times.

  • Unmatched speed (over 100 RPS, two to three times the pulling speed)
  • Can scan walls as much as 50% thinner than the competition (patent pending)
  • Real-time A, B, and C scans, something unique to Magnifi
  • No more false calls due to ghost echoes
  • Virtually no dead zone behind the target pin

Get in touch with us for more information!

Martin VERGE-OSTIGUY
Coordinator, Communications and Marketing
2800, Louis-Lumière, bureau 100
Québec (QC)
G1P 0A4 CANADA
T +1 418-780-1565 x248
F +1 418-780-2354
www.eddyfi.com

 
Visit: Eddyfi

Feedback: ()

Share:
More from "Eddyfi" (5 of 54)
2019-06-01Pulsed Eddy Current Array Design and applications
2019-04-01Eddyfi Technologies Launches the Spyne™ Screening Tool: Leave No Crack Behind!
2018-06-01Detection of Trans-Granular Stress Corrosion Cracking in Complex Line Geometry using Eddy Current Array
2018-06-01Detection of Trans-Granular Stress Corrosion Cracking in Complex Line Geometry using Eddy Current Array
2018-03-01Pulsed Eddy Currents: Improvements in Overcoming Adverse Effects of Galvanized Steel Weather Jacket
... All 54 Details >

More Videos in NDT.net

Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window