where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)

Conference Proceedings, Articles, News, Exhibition, Forum, Network and more

where expertise comes together
- since 1996 -
Beta-Version of this Page View
NDT.net Issue - 2014-06 - Articles
NDT.net Issue: 2014-06
Publication: 5th Conference on Industrial Computed Tomography (iCT) 2014, 25-28 February 2014, Wels, Austria (iCT 2014)
Session: Dimensional Measurement
ARTICLE

An Initial Experimental Study on the Influence of Beam Hardening in X-ray CT for Dimensional Metrology

Joseph J. Lifton1,27, Andrew Malcolm116, John W. McBride33
1Singapore Institute of Manufacturing Technology (SIMTech)32, Singapore, Singapore
2University of Southampton14, Southampton, United Kingdom
3The University of Southampton Malaysia Campus (USMC), Johor, Malaysia

Abstract: X-ray computed tomography (CT) enables the visualisation and dimensional evaluation of both the internal and external geometry of a workpiece, it is therefore well suited for measuring geometric features that are otherwise inaccessible to tactile and optical instruments. Beam hardening is a wellknown physical process that can degrade the quality of CT images and influence edge detection algorithms that define surface points used for dimensional evaluation. The influence of beam hardening on dimensional measurements has yet to be fully characterised; in this work a comparison is made between measurements evaluated with and without beam hardening correction. The results show beam hardening reduces internal dimensions and increases external dimensions; this effect is shown for two different surface determination methods in the absence of scattered radiation

Keywords: beam hardening (30), Computed Tomography (284), Scatter (2), Linearisation (2), beam stop array (1), surface determination (2),
*Keywords are freely formed keywords from the authors and thus you may Search also for similar terms.

View:  


Feedback: ()

Share:
More from "Joseph J. Lifton" (3)
2013-12 The Application of Beam Hardening Correction for Industrial X-ray Computed Tomography
2013-08 Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Failure Analysis and Performance Evaluation
2013-08 The application of voxel size correction in X-ray computed tomography for dimensional metrology
... All 3 Details >
More from "Joseph J. Lifton" (3)
2013-12 The Application of Beam Hardening Correction for Industrial X-ray Computed Tomography
2013-08 Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Failure Analysis and Performance Evaluation
2013-08 The application of voxel size correction in X-ray computed tomography for dimensional metrology
... All 3 Details >
More from "Andrew Malcolm" (5 of 15)
2013-12 Automated recognition of X-Ray CT artefacts in aerospace components
2013-12 Preliminary Study on the impact of sample orientation to CT reconstruction result
2013-12 A Large Scale Multiple Source X-ray Computed Tomography System for Aerospace Applications
2013-12 The Application of Beam Hardening Correction for Industrial X-ray Computed Tomography
2013-08 Development of Unique CT Reconstruction Software for Industrial Applications
... All 15 Details >
More from "John W. McBride" (2)
2013-12 The Application of Beam Hardening Correction for Industrial X-ray Computed Tomography
2013-08 The application of voxel size correction in X-ray computed tomography for dimensional metrology
... All 2 Details >
More from "Singapore Institute of Manufacturing Technology (SIMTech)" (5 of 31)
2018-03New Features of SIMTech’s Unique CT Reconstruction and Visualization Software
2013-12Stochastic Search for 3-d shape registration
2013-12Contour-Based Techniques for Detecting Anomalies in Industrial Structures
2013-12A Large Scale Multiple Source X-ray Computed Tomography System for Aerospace Applications
2013-12CT Multi-Layer Cylindrical Object Delamination Analysis Using Randomized Hough Transformation
... All 31 Details >
More from "University of Southampton" (5 of 13)
2019-03Initial result on the use of tetrahedra-based imaging for limited angle tomography
2019-01Combination of synchrotron computed tomography and acoustic emission measurements for cyclic loading of fibre-reinforced composites
2017-02Comparing cone beam laminographic system trajectories for composite NDT
2015-11A Multi-Component Approach to the Seismic Characterization of Real Multi-Layered Media
2015-11Joint Use of Seismic and Electromagnetic Methods in Geophysical Surveys
... All 13 Details >
Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window