where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)

Conference Proceedings, Articles, News, Exhibition, Forum, Network and more

where expertise comes together
- since 1996 -
Beta-Version of this Page View
NDT.net Issue - 2014-12 - Articles
NDT.net Issue: 2014-12
Publication: 11th European Conference on Non-Destructive Testing (ECNDT 2014), Prague 2014, Oct 6-11 (ECNDT 2014)
Session: Computed Tomography
ARTICLE

Computed Tomography & 3D Metrology - Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Eberhard Neuser15, Alexander Suppes11
Phoenix X-ray; GE Inspection Technologies69, Wunstorf, Germany

Abstract: Computed Tomography (CT) has evolved into an established industrial testing procedure. In addition methods apply, which extend the use of CT for 3D metrology purposes. Within this development, a VDI/VDE (Association of German Engineers) guideline has been defined, which describes how a CT system for use in 3D metrology can be qualified. Applying the VDI/VDE directive on a typical system CT, initially geometric parameters such as length deviation and probing deviation have been determined. A study how important system components such as X-ray tube, detector or manipulator influence the parameters shows optimization potential. In particular the correction of detector and manipulation system is interesting. Finally, the increase of measuring overall performance of the CT system will be demonstrated.

Keywords: Radiographic Testing (RT) (1528), computed tomography (CT) (284), CT (75), X-ray (39), 3D Metrology (5),
*Keywords are freely formed keywords from the authors and thus you may Search also for similar terms.

View:  


Feedback: (1) (1)

Share:
More from "Eberhard Neuser" (5 of 14)
2019-11 Optimization of Image Quality and Throughput at CT Scans of Large Parts
2017-09 Effiziente Unterdrückung von Streustrahlung für produktionsnahe industrielle Computertomographie
2017-09 Innovationen für die Industrielle Röntgenprüfung optimiert für Anforderungen im Bereich schneller CT und hochauflösender Röntgeninspektion
2016-04 ASTM und DICONDE konformes Management von NDT Daten
2015-03 Neue Produkte für die Röntgenprüfung im mobilen Einsatz und in der produktionsnahen Computer Tomographie
... All 14 Details >
More from "Alexander Suppes" (5 of 10)
2019-11 Optimization of Image Quality and Throughput at CT Scans of Large Parts
2019-11 Using Experiment and Simulation to Understand the Effects of Source Filtering on Scatter Reduction for Industrial X-ray Computed Tomography
2017-09 Effiziente Unterdrückung von Streustrahlung für produktionsnahe industrielle Computertomographie
2015-06 High resolution industrial CT systems: Advances and comparison with synchrotron-based CT
2015-03 CT & Metrologie Anwendung der VDI/VDE Richtlinie 2630 und Optimierung des Systems
... All 10 Details >
More from "GE Inspection Technologies" (5 of 68)
2019-11Optimization of Image Quality and Throughput at CT Scans of Large Parts
2019-11Using Experiment and Simulation to Understand the Effects of Source Filtering on Scatter Reduction for Industrial X-ray Computed Tomography
2019-07Register Now: X-ray & CT Forum Germany 9-11 July 2019
2019-04GE Inspection Technologies Commended by Frost & Sullivan for Leading the Industrial Computed Tomography Market with 22% Share
2019-03Utilising Advanced Computed Tomography as NDT Technique in Additive Manufacturing
... All 68 Details >
Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window