where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)

Conference Proceedings, Articles, News, Exhibition, Forum, Network and more

where expertise comes together
- since 1996 -
Beta-Version of this Page View
NDT.net Issue - 2019-03 - Articles
NDT.net Issue: 2019-03
Publication: 9th Conference on Industrial Computed Tomography (iCT) 2019, 13-15 Feb, Padova, Italy (iCT 2019)
Session: Algorithms & Reconstruction
Wed 16:20 Auditorium
ARTICLE

An Interactive Visual Comparison Tool for 3D Volume Datasets represented by Nonlinearly Scaled 1D Line Plots through Space-filling Curves

Johannes Weissenböck111, Bernhard Fröhler16, Eduard Gröller211, Jonathan Sanctorum33, Jan De Beenhouwer315, Jan Sijbers318, Santhosh Ayalur Karunakaran42, Helmuth Hoeller42, Johann Kastner1120, Christoph Heinzl138
1Research Group Computed Tomography; Upper Austrian University of Applied Sciences (FH OÖ)166, Wels, Austria
2Institute of Computer Graphics and Algorithms; Vienna University of Technolog (TU)57, Vienna, Austria
3aInstitute of Computer Graphics and Algorithms bimec-VisionLab, Department of Physics; University of Antwerpen34, Antwerpen, Belgium
4Fischer Advanced Composite Components (FACC)15, Ried, Austria

Abstract: The comparison of many 3D volumes to find subtle differences is tedious, time-consuming and error-prone. Previously we presented Dynamic Volume Lines [1], a novel tool for the interactive visual analysis and comparison of ensembles of 3D volumes, which are linearized using Hilbert spacing-filling curve and represented as 1D line plots. In this paper we further demonstrate the usefulness and capabilities of our method by conducting a detailed visual analysis and evaluation of an artificial specimen from simulated 3D X-Ray Computed Tomography (XCT) and a real-world XCT titanium alloy specimen.

Keywords: Radiographic Testing (RT) (1528), Other Methods (1114), X-ray computed tomography (57), visual analysis (4), comparative visualization (2), Hilbert curve (1), nonlinear scaling (1),
*Keywords are freely formed keywords from the authors and thus you may Search also for similar terms.

View:  


Feedback: ()

Share:
More from "Johannes Weissenböck" (5 of 10)
2019-11 Multimodal Transfer Functions for Talbot-Lau Grating Interferometry Data
2019-03 Experimental investigation on the accuracy of XCT measurement of fiber length in fiber reinforced polymers
2019-03 Tools for the Analysis of Datasets from X-Ray Computed Tomography based on Talbot-Lau Grating Interferometry
2019-03 Simulated grating-based x-ray phase contrast images of CFRP-like objects
2018-08 open_iA: A Framework for Analyzing Industrial Computed Tomography Data
... All 10 Details >
More from "Bernhard Fröhler" (5)
2019-11 Multimodal Transfer Functions for Talbot-Lau Grating Interferometry Data
2019-03 Tools for the Analysis of Datasets from X-Ray Computed Tomography based on Talbot-Lau Grating Interferometry
2018-08 open_iA: A Framework for Analyzing Industrial Computed Tomography Data
2017-03 Parameter-Space Exploration for Computed Tomography Image Analysis Algorithms
2014-06 Uncertainty in CT Metrology: Visualizations for Exploration and Analysis of Geometric Tolerances
... All 5 Details >
More from "Eduard Gröller" (5 of 10)
2019-03 A Novel Approach for Immediate, Interactive CT Data Visualization and Evaluation using GPU-based Segmentation and Visual Analysis
2019-03 Tools for the Analysis of Datasets from X-Ray Computed Tomography based on Talbot-Lau Grating Interferometry
2018-02 Comparative Visualization of Orientation Tensors in Fiber-Reinforced Polymers
2017-03 Comparison of Final Fracture Extraction Techniques for Interrupted In situ Tensile Tests of Glass Fiber Reinforced Polymers
2012-12 Evaluation of Projection-Based Metal-Artifact Reduction for Multi-Material Components
... All 10 Details >
More from "Jonathan Sanctorum" (2)
2019-03 Tools for the Analysis of Datasets from X-Ray Computed Tomography based on Talbot-Lau Grating Interferometry
2019-03 Simulated grating-based x-ray phase contrast images of CFRP-like objects
... All 2 Details >
More from "Jan De Beenhouwer" (5 of 14)
2019-03 Fast detection of cracks in ultrasonically welded parts by inline X-ray inspection
2019-03 CAD-based defect inspection with optimal view angle selection based on polychromatic X-ray projection images
2019-03 Tools for the Analysis of Datasets from X-Ray Computed Tomography based on Talbot-Lau Grating Interferometry
2019-03 A low-cost and easy-to-use phantom for cone-beam geometry calibration of a tomographic X-ray system
2019-03 Simulated grating-based x-ray phase contrast images of CFRP-like objects
... All 14 Details >
More from "Jan Sijbers" (5 of 17)
2019-03 Tools for the Analysis of Datasets from X-Ray Computed Tomography based on Talbot-Lau Grating Interferometry
2019-03 A low-cost and easy-to-use phantom for cone-beam geometry calibration of a tomographic X-ray system
2019-03 Simulated grating-based x-ray phase contrast images of CFRP-like objects
2019-03 Fast detection of cracks in ultrasonically welded parts by inline X-ray inspection
2019-03 CAD-based defect inspection with optimal view angle selection based on polychromatic X-ray projection images
... All 17 Details >
More from "Santhosh Ayalur Karunakaran" (1)
2019-11 Multiscale and Multimodal Approaches for Three-dimensional Materials Characterisation of Fibre Reinforced Polymers by Means of X-ray based NDT Methods
More from "Helmuth Hoeller" (1)
2018-08 Porosity Determination in CFRP by means of X-ray Computed Tomography Methods
More from "Johann Kastner" (5 of 119)
2019-11 At-line X-ray computed tomography of serial parts optimized by numerical simulations
2019-11 Damage characterisation of short glass fibre reinforced polyamide with different fibre content by an interrupted in-situ X-Ray computed tomography test
2019-11 Multiscale and Multimodal Approaches for Three-dimensional Materials Characterisation of Fibre Reinforced Polymers by Means of X-ray based NDT Methods
2019-11 Multimodal Transfer Functions for Talbot-Lau Grating Interferometry Data
2019-11 Improved Visualization of Polymer Foams using Talbot-Lau Grating Interferometry to Reduce Metal Artifacts
... All 119 Details >
More from "Christoph Heinzl" (5 of 37)
2019-11 Multimodal Transfer Functions for Talbot-Lau Grating Interferometry Data
2019-03 Experimental investigation on the accuracy of XCT measurement of fiber length in fiber reinforced polymers
2019-03 Tools for the Analysis of Datasets from X-Ray Computed Tomography based on Talbot-Lau Grating Interferometry
2019-03 Simulated grating-based x-ray phase contrast images of CFRP-like objects
2019-02 Parametric Reconstruction of Glass Fiber-reinforced Polymer Composites from X-ray Projection Data—A Simulation Study
... All 37 Details >
More from "Upper Austrian University of Applied Sciences (FH OÖ)" (5 of 165)
2019-11Multiscale and Multimodal Approaches for Three-dimensional Materials Characterisation of Fibre Reinforced Polymers by Means of X-ray based NDT Methods
2019-11Multimodal Transfer Functions for Talbot-Lau Grating Interferometry Data
2019-11Improved Visualization of Polymer Foams using Talbot-Lau Grating Interferometry to Reduce Metal Artifacts
2019-11At-line X-ray computed tomography of serial parts optimized by numerical simulations
2019-11Damage characterisation of short glass fibre reinforced polyamide with different fibre content by an interrupted in-situ X-Ray computed tomography test
... All 165 Details >
More from "Vienna University of Technolog (TU)" (5 of 56)
2019-11Multimodal Transfer Functions for Talbot-Lau Grating Interferometry Data
2019-08Nachweis von Rissen unter organischen Deckschichten an Schweißverbindungen
2019-03A Novel Approach for Immediate, Interactive CT Data Visualization and Evaluation using GPU-based Segmentation and Visual Analysis
2019-03Tools for the Analysis of Datasets from X-Ray Computed Tomography based on Talbot-Lau Grating Interferometry
2018-02Comparative Visualization of Orientation Tensors in Fiber-Reinforced Polymers
... All 56 Details >
More from "University of Antwerpen" (5 of 33)
2019-05Diffuse versus specular reflection: the influence of hot spots on reflected apparent temperature
2019-05Sublayer composition evaluation of Artwork using active thermography
2019-05Optimised dynamic line scanning thermography for aircraft structures
2019-03Fast detection of cracks in ultrasonically welded parts by inline X-ray inspection
2019-03CAD-based defect inspection with optimal view angle selection based on polychromatic X-ray projection images
... All 33 Details >
More from "Fischer Advanced Composite Components (FACC)" (5 of 14)
2019-11Multiscale and Multimodal Approaches for Three-dimensional Materials Characterisation of Fibre Reinforced Polymers by Means of X-ray based NDT Methods
2018-08Porosity Determination in CFRP by means of X-ray Computed Tomography Methods
2018-02Comparative Visualization of Orientation Tensors in Fiber-Reinforced Polymers
2018-02In-situ damage comparison between fabric-fabric and fabric-UD bonded CFRP
2017-04Zuverlässigkeitsstudie der Aktiven Thermografie bei der Prüfung von Verbundwerkstoffen mittels Probability of Detection Analyse
... All 14 Details >
Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website - More Info
Accept
top
this is debug window